  "name": "Electrophoretic Gel Matrix Operational Specifications and Resolution Thresholds",
  "description": "Comparative technical specifications, matrix concentrations, pore size regimes, running conditions, and molecular separation ranges for agarose and polyacrylamide electrophoresis hydrogels compiled from published laboratory protocols and regulatory standards.",
  "page": "https://casrai.org/compare/agarose-vs-polyacrylamide-gel",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-21T02:45:29Z",
  "temporalCoverage": "2024/2026",
  "spatialCoverage": "Global",
  "columns": [
    {
      "name": "Matrix Type and Formulation",
      "unit": "",
      "description": "Gel polymer composition and nominal percentage"
    },
    {
      "name": "Polymer Percentage",
      "unit": "% w/v",
      "description": "Concentration of polymer in gel matrix"
    },
    {
      "name": "Optimal Target Analyte",
      "unit": "",
      "description": "Primary macromolecular species separated by matrix"
    },
    {
      "name": "Lower Resolution Limit",
      "unit": "",
      "description": "Lower effective sizing boundary"
    },
    {
      "name": "Upper Resolution Limit",
      "unit": "",
      "description": "Upper effective sizing boundary"
    },
    {
      "name": "Sizing Unit",
      "unit": "",
      "description": "Molecular measurement unit: base pairs (bp) or kilodaltons (kDa)"
    },
    {
      "name": "Electrophoresis Buffer",
      "unit": "",
      "description": "Standard operational running buffer system"
    },
    {
      "name": "Operational Voltage",
      "unit": "V",
      "description": "Typical recommended operating voltage"
    }
  ],
  "rows": [
    {
      "Matrix Type and Formulation": "Agarose 0.7%",
      "Polymer Percentage": 0.7,
      "Optimal Target Analyte": "Large genomic DNA and restriction fragments",
      "Lower Resolution Limit": 800,
      "Upper Resolution Limit": 10000,
      "Sizing Unit": "bp",
      "Electrophoresis Buffer": "1x TAE or 1x TBE",
      "Operational Voltage": 90
    },
    {
      "Matrix Type and Formulation": "Agarose 1.0%",
      "Polymer Percentage": 1,
      "Optimal Target Analyte": "Standard PCR products and plasmid restriction digests",
      "Lower Resolution Limit": 400,
      "Upper Resolution Limit": 8000,
      "Sizing Unit": "bp",
      "Electrophoresis Buffer": "1x TAE or 1x TBE",
      "Operational Voltage": 100
    },
    {
      "Matrix Type and Formulation": "Agarose 1.5%",
      "Polymer Percentage": 1.5,
      "Optimal Target Analyte": "Medium-to-small DNA amplicons and total RNA",
      "Lower Resolution Limit": 200,
      "Upper Resolution Limit": 4000,
      "Sizing Unit": "bp",
      "Electrophoresis Buffer": "1x TAE or 1x TBE",
      "Operational Voltage": 100
    },
    {
      "Matrix Type and Formulation": "Agarose 2.0%",
      "Polymer Percentage": 2,
      "Optimal Target Analyte": "Small restriction fragments and short PCR products",
      "Lower Resolution Limit": 100,
      "Upper Resolution Limit": 3000,
      "Sizing Unit": "bp",
      "Electrophoresis Buffer": "1x TBE or 1x TAE",
      "Operational Voltage": 100
    },
    {
      "Matrix Type and Formulation": "Polyacrylamide 6% (PAGE)",
      "Polymer Percentage": 6,
      "Optimal Target Analyte": "High-molecular-weight proteins and large oligos",
      "Lower Resolution Limit": 50,
      "Upper Resolution Limit": 250,
      "Sizing Unit": "kDa",
      "Electrophoresis Buffer": "Tris-Glycine-SDS",
      "Operational Voltage": 120
    },
    {
      "Matrix Type and Formulation": "Polyacrylamide 8% (PAGE)",
      "Polymer Percentage": 8,
      "Optimal Target Analyte": "Medium-to-large molecular weight proteins",
      "Lower Resolution Limit": 30,
      "Upper Resolution Limit": 200,
      "Sizing Unit": "kDa",
      "Electrophoresis Buffer": "Tris-Glycine-SDS",
      "Operational Voltage": 130
    },
    {
      "Matrix Type and Formulation": "Polyacrylamide 10% (PAGE)",
      "Polymer Percentage": 10,
      "Optimal Target Analyte": "General-purpose protein separation and Western blotting",
      "Lower Resolution Limit": 20,
      "Upper Resolution Limit": 150,
      "Sizing Unit": "kDa",
      "Electrophoresis Buffer": "Tris-Glycine-SDS",
      "Operational Voltage": 140
    },
    {
      "Matrix Type and Formulation": "Polyacrylamide 12% (PAGE)",
      "Polymer Percentage": 12,
      "Optimal Target Analyte": "Standard mid-to-small protein fractionation",
      "Lower Resolution Limit": 10,
      "Upper Resolution Limit": 100,
      "Sizing Unit": "kDa",
      "Electrophoresis Buffer": "Tris-Glycine-SDS",
      "Operational Voltage": 150
    },
    {
      "Matrix Type and Formulation": "Polyacrylamide 15% (PAGE)",
      "Polymer Percentage": 15,
      "Optimal Target Analyte": "Small proteins and short peptide fragments",
      "Lower Resolution Limit": 5,
      "Upper Resolution Limit": 50,
      "Sizing Unit": "kDa",
      "Electrophoresis Buffer": "Tris-Glycine-SDS",
      "Operational Voltage": 150
    },
    {
      "Matrix Type and Formulation": "Polyacrylamide 10% (Urea-TBE)",
      "Polymer Percentage": 10,
      "Optimal Target Analyte": "Single-stranded DNA, RNA oligos, and primers",
      "Lower Resolution Limit": 15,
      "Upper Resolution Limit": 200,
      "Sizing Unit": "bp",
      "Electrophoresis Buffer": "1x TBE with 7M Urea",
      "Operational Voltage": 180
    }
  ],
  "sources": [
    {
      "title": "Addgene: Protocol - How to Run an Agarose Gel",
      "url": "https://www.addgene.org/protocols/gel-electrophoresis/",
      "accessed": "2026-11-20"
    },
    {
      "title": "Lee et al. (2012) Agarose Gel Electrophoresis for the Separation of DNA Fragments, J Vis Exp",
      "url": "https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4846332/",
      "accessed": "2026-11-20"
    },
    {
      "title": "Mahmood and Yang (2012) Western Blot: Technique, Theory, and Trouble Shooting, N Am J Med Sci",
      "url": "https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3456489/",
      "accessed": "2026-11-20"
    },
    {
      "title": "OSHA 29 CFR 1910.1000 Table Z-1 - Limits for Air Contaminants (Acrylamide)",
      "url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1000TABLEZ1",
      "accessed": "2026-11-20"
    }
  ]
}