  "name": "Concentration span between 10% and 90% of maximal response by Hill slope",
  "description": "Computed from the Hill-type equation Y = Vmax*X^h/(Khalf^h + X^h) and the log-dose logistic form in the GraphPad Prism guides. At 10% and 90% of maximal response X^h equals Khalf^h/9 and 9*Khalf^h, so the fold span in concentration is 81^(1/h). Values are derived arithmetic, not measured data.",
  "page": "https://casrai.org/compare/hyperbolic-vs-sigmoidal",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-14T07:16:54Z",
  "temporalCoverage": null,
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Hill slope (h)",
      "unit": "",
      "description": ""
    },
    {
      "name": "Fold span in concentration, 10% to 90%",
      "unit": "fold",
      "description": "81 raised to the power 1/h"
    },
    {
      "name": "Span in log10 units",
      "unit": "log10",
      "description": "2*log10(9)/h"
    },
    {
      "name": "Curve description",
      "unit": "",
      "description": "Shape per the Prism guides"
    }
  ],
  "rows": [
    {
      "Hill slope (h)": 0.5,
      "Fold span in concentration, 10% to 90%": 6561,
      "Span in log10 units": 3.82,
      "Curve description": "Shallower than standard: very wide concentration window"
    },
    {
      "Hill slope (h)": 1,
      "Fold span in concentration, 10% to 90%": 81,
      "Span in log10 units": 1.91,
      "Curve description": "Standard slope; Michaelis-Menten/mass action; hyperbolic on a linear X axis"
    },
    {
      "Hill slope (h)": 2,
      "Fold span in concentration, 10% to 90%": 9,
      "Span in log10 units": 0.95,
      "Curve description": "Steeper; sigmoidal on a linear X axis (positive cooperativity in the allosteric model)"
    },
    {
      "Hill slope (h)": 3,
      "Fold span in concentration, 10% to 90%": 4.33,
      "Span in log10 units": 0.64,
      "Curve description": "Steeper still; narrow concentration window"
    }
  ],
  "sources": [
    {
      "title": "GraphPad Prism guide: dose-response, variable slope",
      "url": "https://graphpad.com/guides/prism/latest/curve-fitting/reg_dr_stim_variable.htm",
      "accessed": "2026-11-14"
    },
    {
      "title": "GraphPad Prism guide: allosteric enzyme",
      "url": "https://www.graphpad.com/guides/prism/latest/curve-fitting/reg_allosteric_enzyme.htm",
      "accessed": "2026-11-14"
    }
  ]
}