  "name": "Surgical Dissection Sponges Specification Benchmark",
  "description": "Comparative technical specifications of commercial surgical dissecting sponges (Kittner and peanut models), compiled from FDA UDI records, 510(k) premarket notifications, and manufacturer product specifications under 21 CFR 878.4450.",
  "page": "https://casrai.org/compare/kittner-vs-peanut",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-25T08:35:49Z",
  "temporalCoverage": "2026",
  "spatialCoverage": "United States",
  "columns": [
    {
      "name": "Device Model and Brand",
      "unit": "",
      "description": "Commercial brand and product model name"
    },
    {
      "name": "Sponge Category",
      "unit": "",
      "description": "Functional shape classification under GMDN 13698"
    },
    {
      "name": "Nominal Dimensions",
      "unit": "",
      "description": "Standard physical size and geometric profile"
    },
    {
      "name": "Material Construction",
      "unit": "",
      "description": "Textile composition and structural weave"
    },
    {
      "name": "Packaging and Count",
      "unit": "",
      "description": "Sterility status, count verification card configuration"
    },
    {
      "name": "FDA Regulation and Code",
      "unit": "",
      "description": "CFR regulation number and FDA product code"
    }
  ],
  "rows": [
    {
      "Device Model and Brand": "American Surgical Cotton Kittner",
      "Sponge Category": "Kittner Dissector",
      "Nominal Dimensions": "9/16 in x 1/4 in cylinder",
      "Material Construction": "Tightly rolled cotton chevron tape with barium sulfate filament",
      "Packaging and Count": "Sterile, 5 per count card, single-use",
      "FDA Regulation and Code": "21 CFR 878.4450 (Code GDY / EFQ)"
    },
    {
      "Device Model and Brand": "Symmetry SECTO Dissector (Aspen Surgical)",
      "Sponge Category": "Kittner Dissector",
      "Nominal Dimensions": "5/16 in diameter cylinder",
      "Material Construction": "Machine-rolled cotton tape with stitched reinforcement",
      "Packaging and Count": "Non-sterile bulk or sterile, 5 per pouch, single-use",
      "FDA Regulation and Code": "21 CFR 878.4450 (Code GDY)"
    },
    {
      "Device Model and Brand": "Teleflex Pilling Dissection Sponge",
      "Sponge Category": "Peanut Sponge",
      "Nominal Dimensions": "3/8 in spherical ball",
      "Material Construction": "Folded woven cotton gauze wad with barium sulfate element",
      "Packaging and Count": "Sterile, 5 per foam card (200/box), single-use",
      "FDA Regulation and Code": "21 CFR 878.4450 (Code GDY)"
    },
    {
      "Device Model and Brand": "Medline Specialty XR Dissector",
      "Sponge Category": "Peanut Sponge",
      "Nominal Dimensions": "3/8 in spherical ball with tail",
      "Material Construction": "Multi-ply woven cotton gauze with locator string and x-ray thread",
      "Packaging and Count": "Sterile, 5 per card (100/case), single-use",
      "FDA Regulation and Code": "21 CFR 878.4450 (Code GDY)"
    },
    {
      "Device Model and Brand": "Dukal Surgical Dissectors",
      "Sponge Category": "Kittner and Peanut",
      "Nominal Dimensions": "9/16 in x 1/4 in (Kittner), 3/8 in (Peanut)",
      "Material Construction": "100% woven cotton with radiopaque barium sulfate line",
      "Packaging and Count": "Sterile, 5 per cavity card, single-use",
      "FDA Regulation and Code": "21 CFR 878.4450 (Code GDY)"
    }
  ],
  "sources": [
    {
      "title": "21 CFR 878.4450 Nonabsorbable gauze for internal use",
      "url": "https://www.law.cornell.edu/cfr/text/21/878.4450",
      "accessed": "2026-11-25"
    },
    {
      "title": "openFDA UDI Database: Medical Device Identification",
      "url": "https://api.fda.gov/device/udi.json",
      "accessed": "2026-11-25"
    },
    {
      "title": "openFDA Product Classification Database: Product Code GDY",
      "url": "https://api.fda.gov/device/classification.json",
      "accessed": "2026-11-25"
    }
  ]
}