  "name": "Liquid nitrogen and dry ice: laboratory hazard controls compared",
  "description": "Compares five handling controls and hazards for liquid nitrogen and dry ice in laboratories, compiled from the University of Pennsylvania EHRS cryogens and dry ice SOP, the University of Nevada Reno chemical hygiene plan chapter 8 and NIST Chemistry WebBook phase data. Each cell restates what the cited university procedure states for that material.",
  "page": "https://casrai.org/compare/liquid-nitrogen-vs-dry-ice",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-26T08:25:00Z",
  "temporalCoverage": null,
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Control or hazard",
      "unit": "",
      "description": ""
    },
    {
      "name": "Liquid nitrogen",
      "unit": "",
      "description": ""
    },
    {
      "name": "Dry ice",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Control or hazard": "Face shield for filling or handling",
      "Liquid nitrogen": "Required with cryo-gloves, safety glasses, lab coat, long pants and enclosed shoes (dewar filling)",
      "Dry ice": "Same PPE without the face shield"
    },
    {
      "Control or hazard": "Use in a cold room",
      "Liquid nitrogen": "Not allowed: no cryogens in recirculating-exhaust rooms",
      "Dry ice": "Not allowed: do not work with or store dry ice in cold rooms"
    },
    {
      "Control or hazard": "Gas hazard",
      "Liquid nitrogen": "Nitrogen gas, colorless and odorless; one volume of liquid gives 694 volumes of gas",
      "Dry ice": "Carbon dioxide gas, colorless and odorless; asphyxiation hazard"
    },
    {
      "Control or hazard": "Sealed containers",
      "Liquid nitrogen": "Never seal; sealed warming builds pressure; fill to no more than 80 percent",
      "Dry ice": "Dry ice and alcohol baths are open to the atmosphere"
    },
    {
      "Control or hazard": "Boiling point below -183 C (liquid oxygen formation risk)",
      "Liquid nitrogen": "Yes: about -195.8 C",
      "Dry ice": "No: sublimes at about -78.5 C"
    }
  ],
  "sources": [
    {
      "title": "NIST Chemistry WebBook: nitrogen",
      "url": "https://webbook.nist.gov/cgi/cbook.cgi?ID=C7727379&Mask=4",
      "accessed": "2026-11-17"
    },
    {
      "title": "NIST Chemistry WebBook: carbon dioxide",
      "url": "https://webbook.nist.gov/cgi/cbook.cgi?ID=C124389&Mask=4",
      "accessed": "2026-11-17"
    },
    {
      "title": "University of Pennsylvania EHRS SOP: Cryogens and Dry Ice",
      "url": "https://ehrs.upenn.edu/health-safety/lab-safety/chemical-hygiene-plan/standard-operating-procedures/sop-cryogens-and-dry",
      "accessed": "2026-11-17"
    },
    {
      "title": "University of Nevada, Reno EHS Chemical Hygiene Plan chapter 8",
      "url": "https://www.unr.edu/ehs/safety-policies-and-manuals/chemical-hygiene-plan/chapter-8",
      "accessed": "2026-11-17"
    }
  ]
}