  "name": "Cluster sampling design effect and effective sample size by intraclass correlation and cluster take",
  "description": "Worked values of the clustering design effect deff = 1 + rho(n_bar - 1) and the effective sample size n/deff for a total sample of 1,000, computed by CASRAI from the formulas in the PracTools design effects vignette. Stratification with efficient allocation moves the design effect the other way and is not tabulated.",
  "page": "https://casrai.org/compare/stratified-random-sampling-vs-cluster-sampling",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-22T16:50:00Z",
  "temporalCoverage": "2026",
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Scenario",
      "unit": "",
      "description": ""
    },
    {
      "name": "Intraclass correlation (rho)",
      "unit": "",
      "description": ""
    },
    {
      "name": "Average elements sampled per cluster",
      "unit": "elements",
      "description": ""
    },
    {
      "name": "Design effect (deff)",
      "unit": "",
      "description": ""
    },
    {
      "name": "Effective sample size for n = 1000",
      "unit": "elements",
      "description": ""
    }
  ],
  "rows": [
    {
      "Scenario": "rho 0.01, 5 per cluster",
      "Intraclass correlation (rho)": 0.01,
      "Average elements sampled per cluster": 5,
      "Design effect (deff)": 1.04,
      "Effective sample size for n = 1000": 962
    },
    {
      "Scenario": "rho 0.01, 20 per cluster",
      "Intraclass correlation (rho)": 0.01,
      "Average elements sampled per cluster": 20,
      "Design effect (deff)": 1.19,
      "Effective sample size for n = 1000": 840
    },
    {
      "Scenario": "rho 0.01, 50 per cluster",
      "Intraclass correlation (rho)": 0.01,
      "Average elements sampled per cluster": 50,
      "Design effect (deff)": 1.49,
      "Effective sample size for n = 1000": 671
    },
    {
      "Scenario": "rho 0.05, 5 per cluster",
      "Intraclass correlation (rho)": 0.05,
      "Average elements sampled per cluster": 5,
      "Design effect (deff)": 1.2,
      "Effective sample size for n = 1000": 833
    },
    {
      "Scenario": "rho 0.05, 20 per cluster",
      "Intraclass correlation (rho)": 0.05,
      "Average elements sampled per cluster": 20,
      "Design effect (deff)": 1.95,
      "Effective sample size for n = 1000": 513
    },
    {
      "Scenario": "rho 0.05, 50 per cluster",
      "Intraclass correlation (rho)": 0.05,
      "Average elements sampled per cluster": 50,
      "Design effect (deff)": 3.45,
      "Effective sample size for n = 1000": 290
    },
    {
      "Scenario": "rho 0.10, 5 per cluster",
      "Intraclass correlation (rho)": 0.1,
      "Average elements sampled per cluster": 5,
      "Design effect (deff)": 1.4,
      "Effective sample size for n = 1000": 714
    },
    {
      "Scenario": "rho 0.10, 20 per cluster",
      "Intraclass correlation (rho)": 0.1,
      "Average elements sampled per cluster": 20,
      "Design effect (deff)": 2.9,
      "Effective sample size for n = 1000": 345
    },
    {
      "Scenario": "rho 0.10, 50 per cluster",
      "Intraclass correlation (rho)": 0.1,
      "Average elements sampled per cluster": 50,
      "Design effect (deff)": 5.9,
      "Effective sample size for n = 1000": 169
    }
  ],
  "sources": [
    {
      "title": "Design Effects and Effective Sample Size (PracTools vignette)",
      "url": "https://cran.r-project.org/web/packages/PracTools/vignettes/Design-effects.html",
      "accessed": "2026-11-16"
    },
    {
      "title": "Statistics Canada, Survey Methods and Practices: sample design",
      "url": "https://www150.statcan.gc.ca/n1/pub/12-539-x/2009001/sample-plan-eng.htm",
      "accessed": "2026-11-16"
    }
  ]
}