  "name": "Single-Cell Microfluidic and Microwell Instrumentation Benchmarks",
  "description": "Comparative hardware specifications, operational throughput capacities, droplet generation runtimes, and electrical ratings across commercial single-cell isolation systems, compiled from manufacturer technical specifications and published peer-reviewed benchmarking studies.",
  "page": "https://casrai.org/guides/10x-genomics-chromium",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-29T11:55:00Z",
  "temporalCoverage": "2017-2026",
  "spatialCoverage": "Global",
  "columns": [
    {
      "name": "Instrument Platform",
      "unit": "",
      "description": "Commercial single-cell instrument or platform model"
    },
    {
      "name": "Partitioning Technology",
      "unit": "",
      "description": "Core physical microfluidic or microwell isolation mechanism"
    },
    {
      "name": "Cell Recovery Per Channel",
      "unit": "cells",
      "description": "Nominal recovered single-cell capacity per microfluidic channel or cartridge"
    },
    {
      "name": "Max Cells Per Run",
      "unit": "cells",
      "description": "Maximum cell recovery achievable in a single instrument run"
    },
    {
      "name": "Partitioning Run Time",
      "unit": "minutes",
      "description": "Active instrument run time for cell encapsulation or well loading"
    },
    {
      "name": "Instrument Weight",
      "unit": "kg",
      "description": "Net physical weight of the benchtop instrument"
    },
    {
      "name": "Nominal Power Rating",
      "unit": "W",
      "description": "Maximum or nominal electrical power consumption rating"
    }
  ],
  "rows": [
    {
      "Instrument Platform": "Chromium Controller",
      "Partitioning Technology": "Next GEM microfluidic droplets",
      "Cell Recovery Per Channel": 10000,
      "Max Cells Per Run": 80000,
      "Partitioning Run Time": 18,
      "Instrument Weight": 5.6,
      "Nominal Power Rating": 25
    },
    {
      "Instrument Platform": "Chromium iX",
      "Partitioning Technology": "Next GEM microfluidic droplets",
      "Cell Recovery Per Channel": 20000,
      "Max Cells Per Run": 160000,
      "Partitioning Run Time": 18,
      "Instrument Weight": 18.8,
      "Nominal Power Rating": 250
    },
    {
      "Instrument Platform": "Chromium X",
      "Partitioning Technology": "Next GEM microfluidic droplets",
      "Cell Recovery Per Channel": 20000,
      "Max Cells Per Run": 320000,
      "Partitioning Run Time": 18,
      "Instrument Weight": 18.8,
      "Nominal Power Rating": 250
    },
    {
      "Instrument Platform": "Chromium Connect",
      "Partitioning Technology": "Automated robotic microfluidic droplets",
      "Cell Recovery Per Channel": 10000,
      "Max Cells Per Run": 80000,
      "Partitioning Run Time": 20,
      "Instrument Weight": 115,
      "Nominal Power Rating": 600
    },
    {
      "Instrument Platform": "BD Rhapsody Express",
      "Partitioning Technology": "Cartridge gravitational microwells",
      "Cell Recovery Per Channel": 20000,
      "Max Cells Per Run": 40000,
      "Partitioning Run Time": 30,
      "Instrument Weight": 8.5,
      "Nominal Power Rating": 40
    }
  ],
  "sources": [
    {
      "title": "Massively parallel digital transcriptional profiling of single cells",
      "url": "https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5241818/",
      "accessed": "2026-11-20"
    },
    {
      "title": "The Comparison of Two Single-cell Sequencing Platforms: BD Rhapsody and 10x Genomics Chromium",
      "url": "https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7770630/",
      "accessed": "2026-11-20"
    },
    {
      "title": "Performance comparison of high throughput single-cell RNA-Seq platforms in complex tissues",
      "url": "https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11408078/",
      "accessed": "2026-11-20"
    }
  ]
}