  "name": "Adaptive Optics Hardware and Operational Specifications Across Research Facilities",
  "description": "Comparative technical specifications of major adaptive optics systems across astronomical observatories, biomedical microscopy platforms, and commercial MEMS deformable mirrors, compiled from facility technical documentation and manufacturer engineering data sheets.",
  "page": "https://casrai.org/guides/adaptive-optics",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-14T03:55:17Z",
  "temporalCoverage": "2020/2026",
  "spatialCoverage": "Global",
  "columns": [
    {
      "name": "System or Model",
      "unit": "",
      "description": "Identifier of the adaptive optics instrument or deformable mirror device"
    },
    {
      "name": "Application Domain",
      "unit": "",
      "description": "Primary scientific or engineering domain"
    },
    {
      "name": "Actuator Count",
      "unit": "",
      "description": "Total active actuators or correction elements"
    },
    {
      "name": "Actuator Pitch",
      "unit": "µm",
      "description": "Center-to-center actuator physical spacing"
    },
    {
      "name": "Wavefront Stroke",
      "unit": "µm",
      "description": "Maximum peak-to-valley wavefront stroke correction"
    },
    {
      "name": "Loop Frame Rate",
      "unit": "Hz",
      "description": "Operational closed-loop control update rate"
    },
    {
      "name": "Wavefront Sensor",
      "unit": "",
      "description": "Primary wavefront sensor architecture"
    },
    {
      "name": "Operational Facility or Manufacturer",
      "unit": "",
      "description": "Observatory, research institute, or hardware manufacturer"
    }
  ],
  "rows": [
    {
      "System or Model": "Boston Micromachines Multi-DM",
      "Application Domain": "MEMS Deformable Mirror",
      "Actuator Count": 140,
      "Actuator Pitch": 400,
      "Wavefront Stroke": 7,
      "Loop Frame Rate": 2000,
      "Wavefront Sensor": "Shack-Hartmann or Interferometer",
      "Operational Facility or Manufacturer": "Boston Micromachines Corporation"
    },
    {
      "System or Model": "Boston Micromachines 492-DM",
      "Application Domain": "MEMS Deformable Mirror",
      "Actuator Count": 492,
      "Actuator Pitch": 400,
      "Wavefront Stroke": 7,
      "Loop Frame Rate": 45000,
      "Wavefront Sensor": "Shack-Hartmann or Interferometer",
      "Operational Facility or Manufacturer": "Boston Micromachines Corporation"
    },
    {
      "System or Model": "Boston Micromachines Kilo-DM",
      "Application Domain": "MEMS Deformable Mirror",
      "Actuator Count": 952,
      "Actuator Pitch": 300,
      "Wavefront Stroke": 3,
      "Loop Frame Rate": 45000,
      "Wavefront Sensor": "Shack-Hartmann or Pyramid",
      "Operational Facility or Manufacturer": "Boston Micromachines Corporation"
    },
    {
      "System or Model": "Boston Micromachines 2K-DM",
      "Application Domain": "Extreme Adaptive Optics",
      "Actuator Count": 2040,
      "Actuator Pitch": 400,
      "Wavefront Stroke": 7,
      "Loop Frame Rate": 30000,
      "Wavefront Sensor": "Pyramid Wavefront Sensor",
      "Operational Facility or Manufacturer": "Boston Micromachines Corporation"
    },
    {
      "System or Model": "Subaru Telescope SCExAO",
      "Application Domain": "Extreme Astronomical AO",
      "Actuator Count": 2000,
      "Actuator Pitch": 400,
      "Wavefront Stroke": 7,
      "Loop Frame Rate": 3500,
      "Wavefront Sensor": "Pyramid Wavefront Sensor",
      "Operational Facility or Manufacturer": "Subaru Telescope (NAOJ)"
    },
    {
      "System or Model": "Subaru Telescope AO188",
      "Application Domain": "Facility Astronomical AO",
      "Actuator Count": 188,
      "Actuator Pitch": 1200,
      "Wavefront Stroke": 4,
      "Loop Frame Rate": 1000,
      "Wavefront Sensor": "Curvature Wavefront Sensor",
      "Operational Facility or Manufacturer": "Subaru Telescope (NAOJ)"
    },
    {
      "System or Model": "Keck Observatory NGAO System",
      "Application Domain": "Facility Astronomical AO",
      "Actuator Count": 349,
      "Actuator Pitch": 1000,
      "Wavefront Stroke": 4,
      "Loop Frame Rate": 1000,
      "Wavefront Sensor": "Shack-Hartmann (NGS / Sodium LGS)",
      "Operational Facility or Manufacturer": "W. M. Keck Observatory"
    },
    {
      "System or Model": "ESO VLT SPHERE SAXO",
      "Application Domain": "Extreme Exoplanet AO",
      "Actuator Count": 1377,
      "Actuator Pitch": 450,
      "Wavefront Stroke": 5,
      "Loop Frame Rate": 1380,
      "Wavefront Sensor": "Shack-Hartmann (Visible)",
      "Operational Facility or Manufacturer": "European Southern Observatory (VLT)"
    },
    {
      "System or Model": "Deep-Tissue Multiphoton AO",
      "Application Domain": "Biomedical Microscopy",
      "Actuator Count": 140,
      "Actuator Pitch": 400,
      "Wavefront Stroke": 7,
      "Loop Frame Rate": 1000,
      "Wavefront Sensor": "Sensorless Modal Metric (Zernike)",
      "Operational Facility or Manufacturer": "Academic & Bio-imaging Labs"
    }
  ],
  "sources": [
    {
      "title": "Boston Micromachines Standard Deformable Mirrors",
      "url": "https://bostonmicromachines.com/products/deformable-mirrors/standard-deformable-mirrors/",
      "accessed": "2026-11-13"
    },
    {
      "title": "Subaru Telescope SCExAO Instrument Overview",
      "url": "https://subarutelescope.org/en/research/instrument/scexao.html",
      "accessed": "2026-11-13"
    },
    {
      "title": "Keck Observatory Adaptive Optics Facility",
      "url": "https://www2.keck.hawaii.edu/optics/ao/",
      "accessed": "2026-11-13"
    },
    {
      "title": "ESO Paranal Instrumentation Reference",
      "url": "https://www.eso.org/sci/facilities/paranal/instruments.html",
      "accessed": "2026-11-13"
    },
    {
      "title": "Light: Science & Applications (PMC10641083)",
      "url": "https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10641083/",
      "accessed": "2026-11-13"
    }
  ]
}