{
  "name": "Marker-gene sequence units compared: closed-reference OTU, de novo OTU, ASV and sOTU",
  "description": "Compares how four units used in amplicon (marker-gene) sequencing analysis are defined, whether they depend on a reference database, and the advantages the primary literature states for each. Compiled from Callahan et al. 2017 (ISME J), Callahan et al. 2016 (Nat Methods) and Amir et al. 2017 (mSystems).",
  "page": "https://casrai.org/guides/amplicon-sequence-variants",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-21T06:15:02Z",
  "temporalCoverage": null,
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Unit",
      "unit": "",
      "description": ""
    },
    {
      "name": "How it is defined",
      "unit": "",
      "description": ""
    },
    {
      "name": "Depends on a reference database",
      "unit": "",
      "description": ""
    },
    {
      "name": "Advantages stated in the source",
      "unit": "",
      "description": ""
    },
    {
      "name": "Primary source",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Unit": "Closed-reference OTU",
      "How it is defined": "Reads matched to a reference database and grouped under a fixed dissimilarity threshold (typically 3%)",
      "Depends on a reference database": "Yes",
      "Advantages stated in the source": "Computational cost scales linearly with study size; independently processed datasets merge simply; supports forward prediction",
      "Primary source": "Callahan et al. 2017"
    },
    {
      "Unit": "De novo OTU",
      "How it is defined": "Reads clustered within one dataset under a fixed dissimilarity threshold (typically 3%)",
      "Depends on a reference database": "No",
      "Advantages stated in the source": "Accurate diversity measurement; works where reference databases are shallow",
      "Primary source": "Callahan et al. 2017"
    },
    {
      "Unit": "ASV (exact sequence variant)",
      "How it is defined": "Exact sequence inferred after modelling and removing amplification and sequencing errors, resolved to single-nucleotide differences",
      "Depends on a reference database": "No (identified independently of a database)",
      "Advantages stated in the source": "Combines the advantages of both OTU strategies; consistent labels across studies; computation scales linearly with samples",
      "Primary source": "Callahan et al. 2017; Callahan et al. 2016"
    },
    {
      "Unit": "sOTU (Deblur output)",
      "How it is defined": "Putative error-free sequences obtained with error profiles from Illumina MiSeq or HiSeq data",
      "Depends on a reference database": "No",
      "Advantages stated in the source": "Single-nucleotide resolution for uses needing higher specificity, such as clinical and food-safety work",
      "Primary source": "Amir et al. 2017"
    }
  ],
  "sources": [
    {
      "title": "Exact sequence variants should replace operational taxonomic units in marker-gene data analysis",
      "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC5702726/",
      "accessed": "2026-11-21"
    },
    {
      "title": "DADA2: high-resolution sample inference from Illumina amplicon data",
      "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC4927377/",
      "accessed": "2026-11-21"
    },
    {
      "title": "Deblur rapidly resolves single-nucleotide community sequence patterns",
      "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC5340863/",
      "accessed": "2026-11-21"
    }
  ]
}