  "name": "Stated preparation conditions for amine-reactive antibody labeling",
  "description": "Compiled from three readable vendor and technical sources: the stated tolerances, limits and recommended ranges for buffers, additives, purity, concentration, pH and degree of labeling when labeling antibodies with NHS-ester chemistry. Each row records what the named sources state; vendor protocols may differ.",
  "page": "https://casrai.org/guides/antibody-conjugation",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-23T10:25:00Z",
  "temporalCoverage": null,
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Condition or additive",
      "unit": "",
      "description": ""
    },
    {
      "name": "Stated limit or behaviour",
      "unit": "",
      "description": ""
    },
    {
      "name": "Source",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Condition or additive": "Tris and glycine buffers",
      "Stated limit or behaviour": "Incompatible with NHS-ester reactions; may be added at the end to quench. Remove by dialysis or desalting before labeling",
      "Source": "Thermo Fisher; AAT Bioquest; Bio-Synthesis"
    },
    {
      "Condition or additive": "BSA or gelatin carrier",
      "Stated limit or behaviour": "Remove before labeling; stabilised antibodies label poorly",
      "Source": "AAT Bioquest; Bio-Synthesis"
    },
    {
      "Condition or additive": "Sodium azide",
      "Stated limit or behaviour": "Generally tolerated up to 3 mM (0.02%); higher levels interfere",
      "Source": "Thermo Fisher"
    },
    {
      "Condition or additive": "Thimerosal",
      "Stated limit or behaviour": "Generally tolerated up to 0.02 mM; higher levels interfere",
      "Source": "Thermo Fisher"
    },
    {
      "Condition or additive": "Glycerol",
      "Stated limit or behaviour": "Impure glycerol or 20-50% glycerol lowers efficiency",
      "Source": "Thermo Fisher"
    },
    {
      "Condition or additive": "Antibody purity",
      "Stated limit or behaviour": "More than 90%, preferably more than 95%; crude serum, ascites and supernatant need purification",
      "Source": "Bio-Synthesis"
    },
    {
      "Condition or additive": "Antibody concentration",
      "Stated limit or behaviour": "Above 0.5 mg/mL (Bio-Synthesis); 2-10 mg/mL recommended, efficiency reduced below 2 mg/mL (AAT Bioquest)",
      "Source": "Bio-Synthesis; AAT Bioquest"
    },
    {
      "Condition or additive": "Reaction buffer pH",
      "Stated limit or behaviour": "NHS esters react at pH 7.2-9; typical buffers pH 7.2-8.5 (Thermo Fisher); AAT Bioquest protocol uses pH 8.5 +/- 0.5",
      "Source": "Thermo Fisher; AAT Bioquest"
    },
    {
      "Condition or additive": "Degree of labeling",
      "Stated limit or behaviour": "Optimum for most antibodies 2-10 depending on dye and protein; above about 6 tends to reduce fluorescence",
      "Source": "AAT Bioquest"
    }
  ],
  "sources": [
    {
      "title": "Bio-Synthesis, Antibody labeling and conjugation methods",
      "url": "https://www.biosyn.com/tew/antibody-labeling-and-conjugation-methods.aspx",
      "accessed": "2026-11-15"
    },
    {
      "title": "AAT Bioquest, Antibody conjugation protocol",
      "url": "https://www.aatbio.com/resources/application-notes/antibody-conjugation-protocol",
      "accessed": "2026-11-15"
    },
    {
      "title": "Thermo Fisher, Amine-reactive crosslinker chemistry",
      "url": "https://www.thermofisher.com/us/en/home/life-science/protein-biology/protein-biology-learning-center/protein-biology-resource-library/pierce-protein-methods/amine-reactive-crosslinker-chemistry.html",
      "accessed": "2026-11-15"
    }
  ]
}