  "name": "NBIS maximum bridge inspection intervals by inspection type (Method 1 and Method 2), 23 CFR 650.311",
  "description": "Maximum inspection intervals in months for routine, underwater and nonredundant steel tension member inspections under the National Bridge Inspection Standards, compiled from the text of 23 CFR 650.311: Method 1 regular, reduced and extended intervals, the Method 2 risk-category intervals, and the reduced-interval trigger.",
  "page": "https://casrai.org/guides/bridge-engineering",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-12T22:25:07Z",
  "temporalCoverage": "2026",
  "spatialCoverage": "United States",
  "columns": [
    {
      "name": "Inspection type",
      "unit": "",
      "description": ""
    },
    {
      "name": "Method 1 regular interval",
      "unit": "months",
      "description": ""
    },
    {
      "name": "Method 1 reduced interval",
      "unit": "months",
      "description": ""
    },
    {
      "name": "Method 1 extended interval",
      "unit": "months",
      "description": ""
    },
    {
      "name": "Method 2 risk-category intervals",
      "unit": "months",
      "description": ""
    },
    {
      "name": "Reduced-interval trigger (NBI rating)",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Inspection type": "Routine inspection",
      "Method 1 regular interval": 24,
      "Method 1 reduced interval": 12,
      "Method 1 extended interval": 48,
      "Method 2 risk-category intervals": "12, 24, 48, 72",
      "Reduced-interval trigger (NBI rating)": "Reduced: deck, superstructure, substructure or culvert condition rating 3 or less, or Scour Condition Rating 3 or less"
    },
    {
      "Inspection type": "Underwater inspection",
      "Method 1 regular interval": 60,
      "Method 1 reduced interval": 24,
      "Method 1 extended interval": 72,
      "Method 2 risk-category intervals": "24, 60, 72",
      "Reduced-interval trigger (NBI rating)": "Reduced: underwater, channel or channel protection condition 3 or less, or Scour Condition Rating 3 or less"
    },
    {
      "Inspection type": "Nonredundant steel tension member (NSTM) inspection",
      "Method 1 regular interval": 24,
      "Method 1 reduced interval": 12,
      "Method 1 extended interval": 48,
      "Method 2 risk-category intervals": "12, 24, 48",
      "Reduced-interval trigger (NBI rating)": "Reduced: NSTM Inspection Condition rating 4 or less"
    }
  ],
  "sources": [
    {
      "title": "23 CFR 650.311 Inspection interval",
      "url": "https://www.law.cornell.edu/cfr/text/23/650.311",
      "accessed": "2026-11-12"
    }
  ]
}