  "name": "Investigation and follow-up duties for drug-product problems: 21 CFR 211.192, 211.198, ICH Q10 and FDA 2006 guidance",
  "description": "Side-by-side compilation of what four official texts say about when a problem must be investigated, how far the investigation extends, and what must be recorded or evaluated. Compiled from the CFR text of 21 CFR 211.192 and 211.198, ICH Q10 (Step 4, 2008) and the FDA guidance Quality Systems Approach to Pharmaceutical CGMP Regulations (2006).",
  "page": "https://casrai.org/guides/capa-pharmaceutical",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-19T16:17:39Z",
  "temporalCoverage": "2006/2008",
  "spatialCoverage": "United States; international (ICH)",
  "columns": [
    {
      "name": "Source",
      "unit": "",
      "description": ""
    },
    {
      "name": "What triggers the investigation or action",
      "unit": "",
      "description": ""
    },
    {
      "name": "Scope or depth",
      "unit": "",
      "description": ""
    },
    {
      "name": "Record or follow-up expectation",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Source": "21 CFR 211.192 (binding regulation)",
      "What triggers the investigation or action": "Any unexplained discrepancy, or failure of a batch or any of its components to meet specifications",
      "Scope or depth": "Thorough investigation whether or not the batch is distributed; extends to other batches of the same product and other products that may be associated",
      "Record or follow-up expectation": "Written record of the investigation, including conclusions and follow-up"
    },
    {
      "Source": "21 CFR 211.198 (binding regulation)",
      "What triggers the investigation or action": "Complaints, including those involving possible failure to meet a specification",
      "Scope or depth": "Quality control unit reviews and decides whether an investigation under 211.192 is needed",
      "Record or follow-up expectation": "Complaint record; findings and follow-up if investigated, or the reason and the responsible person's name if not"
    },
    {
      "Source": "ICH Q10 section 3.2.2 (guideline)",
      "What triggers the investigation or action": "Complaints, rejections, non-conformances, recalls, deviations, audits, inspections and findings, and monitoring trends",
      "Scope or depth": "Structured approach to determine root cause; effort, formality and documentation commensurate with risk (ICH Q9)",
      "Record or follow-up expectation": "Should result in product and process improvements and enhanced understanding; outputs link to change management (3.2.3)"
    },
    {
      "Source": "FDA guidance 2006, section on CAPA (nonbinding)",
      "What triggers the investigation or action": "Nonconformance reports, rejections, returns, complaints, audits, data and risk assessment, management review decisions",
      "Scope or depth": "Evaluate need for action relative to consequences; investigate root cause; take action within a defined timeframe",
      "Record or follow-up expectation": "Document actions taken; evaluate effectiveness; preventive actions also evaluated, recorded and monitored"
    },
    {
      "Source": "ICH Q10 section 2.7 (guideline)",
      "What triggers the investigation or action": "Outsourced activities and purchased materials",
      "Scope or depth": "Company ultimately responsible; supplier assessment before selection and monitoring and review afterwards",
      "Record or follow-up expectation": "Written agreement; identify and implement needed improvements"
    }
  ],
  "sources": [
    {
      "title": "ICH Q10 Pharmaceutical Quality System",
      "url": "https://database.ich.org/sites/default/files/Q10%20Guideline.pdf",
      "accessed": "2026-11-19"
    },
    {
      "title": "FDA Quality Systems Approach to Pharmaceutical CGMP Regulations",
      "url": "https://www.fda.gov/media/71023/download",
      "accessed": "2026-11-19"
    },
    {
      "title": "21 CFR 211.192",
      "url": "https://www.law.cornell.edu/cfr/text/21/211.192",
      "accessed": "2026-11-19"
    },
    {
      "title": "21 CFR 211.198",
      "url": "https://www.law.cornell.edu/cfr/text/21/211.198",
      "accessed": "2026-11-19"
    }
  ]
}