  "name": "Pump cavitation types: cause and stated remedy",
  "description": "Five cavitation conditions in centrifugal pumps compiled from a single trade-engineering article, giving each condition's stated cause and the remedy the article ties to it or to the closest related guidance.",
  "page": "https://casrai.org/guides/centrifugal-pump-cavitation",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-21T10:25:45Z",
  "temporalCoverage": null,
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Cavitation type",
      "unit": "",
      "description": ""
    },
    {
      "name": "Stated cause",
      "unit": "",
      "description": ""
    },
    {
      "name": "Stated remedy",
      "unit": "",
      "description": ""
    },
    {
      "name": "Source",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Cavitation type": "Vaporization",
      "Stated cause": "Liquid accelerates into the impeller eye, pressure drops and the liquid boils",
      "Stated remedy": "Keep NPSHa above NPSHr: lower the pump or raise suction level, enlarge suction piping, cut fitting losses, limit screens and filters, cool the fluid",
      "Source": "Pumps and Systems"
    },
    {
      "Cavitation type": "Turbulence",
      "Stated cause": "Elbows, valves, filters or strainers unsuited to the liquid or flow create vortices and pressure differences at the inlet",
      "Stated remedy": "General advice: avoid turbulent flow at the intake; long-radius bends and full-bore valves",
      "Source": "Pumps and Systems"
    },
    {
      "Cavitation type": "Vane syndrome",
      "Stated cause": "Impeller too large or housing coating too thick reduces clearance, raising velocity and lowering pressure",
      "Stated remedy": "Impeller design and pump sizing",
      "Source": "Pumps and Systems"
    },
    {
      "Cavitation type": "Internal recirculation",
      "Stated cause": "Pump cannot discharge at the required rate, e.g. closed discharge valve, so liquid recirculates around the impeller",
      "Stated remedy": "Maintain minimum flow with bypass lines, control valves or variable speed pumping",
      "Source": "Pumps and Systems"
    },
    {
      "Cavitation type": "Air aspiration",
      "Stated cause": "Air enters through failing valves or loose joints and forms bubbles that collapse under pump pressure",
      "Stated remedy": "Seal pipe connections, maintain submergence and suction head, prime properly, avoid intake vortices",
      "Source": "Pumps and Systems"
    }
  ],
  "sources": [
    {
      "title": "Reducing Cavitation in Centrifugal Pumps (Pumps and Systems)",
      "url": "https://pumpsandsystems.com/reducing-cavitation-centrifugal-pumps",
      "accessed": "2026-11-21"
    }
  ]
}