  "name": "What each GMP/quality source says about relying on a supplier's certificate of analysis",
  "description": "Compares, across five regulatory or guidance sources, the minimum check retained by the receiving party, whether a supplier certificate can replace other testing, the supplier-validation condition, and the CoA content stated. Compiled from the primary texts of 21 CFR 211.84, 21 CFR 111.75, ICH Q7 (FDA-hosted text) and the WHO model certificate of analysis annex.",
  "page": "https://casrai.org/guides/certificate-of-analysis-coa",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-14T17:24:56Z",
  "temporalCoverage": "Current texts as of 2026-11-14",
  "spatialCoverage": "United States; international guidance",
  "columns": [
    {
      "name": "Source and scope",
      "unit": "",
      "description": ""
    },
    {
      "name": "Minimum own test or check by receiver",
      "unit": "",
      "description": ""
    },
    {
      "name": "Supplier certificate may replace other testing?",
      "unit": "",
      "description": ""
    },
    {
      "name": "Condition on supplier reliability",
      "unit": "",
      "description": ""
    },
    {
      "name": "Stated CoA content requirement",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Source and scope": "21 CFR 211.84(d)(2), drug-product components",
      "Minimum own test or check by receiver": "At least one specific identity test",
      "Supplier certificate may replace other testing?": "Yes, for conformity with purity, strength and quality specifications (report of analysis)",
      "Condition on supplier reliability": "Manufacturer establishes reliability of supplier analyses through appropriate validation at appropriate intervals",
      "Stated CoA content requirement": "Not specified in this paragraph"
    },
    {
      "Source and scope": "21 CFR 211.84(d)(3), containers and closures",
      "Minimum own test or check by receiver": "At least visual identification",
      "Supplier certificate may replace other testing?": "Yes (certificate of testing)",
      "Condition on supplier reliability": "Manufacturer establishes reliability of supplier test results; validated at appropriate intervals",
      "Stated CoA content requirement": "Not specified in this paragraph"
    },
    {
      "Source and scope": "21 CFR 111.75(a), dietary supplement components",
      "Minimum own test or check by receiver": "At least one appropriate identity test for any dietary-ingredient component",
      "Supplier certificate may replace other testing?": "Yes, for other components (certificate of analysis)",
      "Condition on supplier reliability": "Supplier qualified first by confirming reliability; records kept; periodic re-confirmation; QC approves qualification basis",
      "Stated CoA content requirement": "Describes test or examination methods, test limits and actual results"
    },
    {
      "Source and scope": "ICH Q7 7.3 (APIs), incoming materials",
      "Minimum own test or check by receiver": "At least one identity test per batch of material",
      "Supplier certificate may replace other testing?": "Yes, if manufacturer has a system to evaluate suppliers",
      "Condition on supplier reliability": "Complete analyses on at least three batches before reducing in-house testing; complete analysis at appropriate intervals compared with CoAs; reliability checked at regular intervals",
      "Stated CoA content requirement": "Section 11.4 (for API/intermediate CoAs): name and grade, batch number, release date, expiry or retest date, tests with limits and numerical results, dated signature of quality-unit personnel, original manufacturer name, address and telephone"
    },
    {
      "Source and scope": "WHO model CoA (TRS Annex 4), QC laboratories",
      "Minimum own test or check by receiver": "Not a receiving rule; model for issuing laboratories",
      "Supplier certificate may replace other testing?": "Not addressed",
      "Condition on supplier reliability": "Not addressed",
      "Stated CoA content requirement": "Issuing lab name and address, CoA ID and page x of y, sample and batch details, original manufacturer, specifications with test procedure references, results versus limits, conclusion, dated signature; ISO/IEC 17025 accreditation reference where related to the analysis"
    }
  ],
  "sources": [
    {
      "title": "21 CFR 211.84 Testing and approval or rejection of components, drug product containers, and closures",
      "url": "https://www.law.cornell.edu/cfr/text/21/211.84",
      "accessed": "2026-11-14"
    },
    {
      "title": "21 CFR 111.75 What must you do to determine whether specifications are met (dietary supplements)",
      "url": "https://www.law.cornell.edu/cfr/text/21/111.75",
      "accessed": "2026-11-14"
    },
    {
      "title": "ICH Q7 Good Manufacturing Practice Guidance for Active Pharmaceutical Ingredients (FDA)",
      "url": "https://fda.gov/media/71518/download",
      "accessed": "2026-11-14"
    },
    {
      "title": "WHO Model certificate of analysis (TRS Annex 4)",
      "url": "https://cdn.who.int/media/docs/default-source/medicines/norms-and-standards/guidelines/quality-control/who-model-certificate-of-analysis.pdf",
      "accessed": "2026-11-14"
    }
  ]
}