  "name": "Design requirements for Listeria monocytogenes challenge tests: growth potential versus maximum growth rate",
  "description": "Side-by-side comparison of design requirements for the two challenge-test types in the EURL Lm laboratory-competence guidance (version 3, 2023), which restates EN ISO 20976-1 and the EURL technical guidance document. Compiled from the European Commission PDF by aligning each requirement across the two test types.",
  "page": "https://casrai.org/guides/challenge-testing",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-26T10:15:00Z",
  "temporalCoverage": "2023",
  "spatialCoverage": "European Union",
  "columns": [
    {
      "name": "Design element",
      "unit": "",
      "description": ""
    },
    {
      "name": "Growth potential test",
      "unit": "",
      "description": ""
    },
    {
      "name": "Maximum growth rate test",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Design element": "Question answered",
      "Growth potential test": "Difference between highest and initial log10 cfu/g under foreseeable storage",
      "Maximum growth rate test": "Growth rate of a single strain at one constant temperature"
    },
    {
      "Design element": "Minimum batches",
      "Growth potential test": "3 batches, ideally selected at different times",
      "Maximum growth rate test": "Fewer than 3 allowed with a justification from the ISO 20976-1 inter-batch calculator"
    },
    {
      "Design element": "Strains",
      "Growth potential test": "At least 2, used as a mixture",
      "Maximum growth rate test": "At least 2, each tested individually"
    },
    {
      "Design element": "Target inoculum",
      "Growth potential test": "About 100 cfu/g (50-200); volume up to 1% of unit mass",
      "Maximum growth rate test": "About 100 cfu/g (50-200); volume up to 1% of unit mass"
    },
    {
      "Design element": "Minimum sampling points",
      "Growth potential test": "At least 5",
      "Maximum growth rate test": "At least 8"
    },
    {
      "Design element": "Storage",
      "Growth potential test": "Justified time/temperature profile per cold-chain stage (default 7, 7 and 10 C)",
      "Maximum growth rate test": "One defined constant temperature"
    },
    {
      "Design element": "Natural contamination found at time zero",
      "Growth potential test": "Test may continue only if natural level is no higher than the artificial level",
      "Maximum growth rate test": "Test must be stopped"
    },
    {
      "Design element": "Final outcome",
      "Growth potential test": "Highest growth potential across batches",
      "Maximum growth rate test": "Mean of the batch maximum growth rates with its standard deviation"
    }
  ],
  "sources": [
    {
      "title": "EURL Lm guidance document to evaluate the competence of laboratories implementing challenge tests and durability studies, version 3",
      "url": "https://food.ec.europa.eu/system/files/2023-02/biosafety_fh_mc_guidance-comp-labs.pdf",
      "accessed": "2026-11-18"
    }
  ]
}