  "name": "Chemotaxis assay readouts and interpretation limits",
  "description": "Original comparison of measurement locations and interpretation limits, compiled from a manufacturer analysis manual and two primary research-methods papers. The source column identifies the evidence for each row; this is a qualitative methods crosswalk, not measured performance data.",
  "page": "https://casrai.org/guides/chemotaxis-assay",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-16T02:55:00Z",
  "temporalCoverage": null,
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Readout",
      "unit": "",
      "description": ""
    },
    {
      "name": "Measured location or object",
      "unit": "",
      "description": ""
    },
    {
      "name": "Reported quantity",
      "unit": "",
      "description": ""
    },
    {
      "name": "Interpretation limit",
      "unit": "",
      "description": ""
    },
    {
      "name": "Primary source",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Readout": "Filter endpoint count",
      "Measured location or object": "Porous membrane boundary",
      "Reported quantity": "Number of cells migrating into or through a filter",
      "Interpretation limit": "Boundary crossing also includes random motility; gradient comparisons are needed to distinguish direction sensing",
      "Primary source": "Szatmary and Nossal, Introduction and section 3.4"
    },
    {
      "Readout": "Repeated insert fluorescence",
      "Measured location or object": "Underside of porous insert",
      "Reported quantity": "Fluorescent signal over repeated observations",
      "Interpretation limit": "Signal reflects arrival and departure at the insert; it is not necessarily cumulative migration",
      "Primary source": "Prangley et al., Representative Results and Discussion"
    },
    {
      "Readout": "Under-agarose boundary count",
      "Measured location or object": "Edge of cell well facing attractant source",
      "Reported quantity": "Cells leaving the well beneath agarose",
      "Interpretation limit": "Concentration and gradient vary; attractant-free controls do not automatically match chemokinesis",
      "Primary source": "Szatmary and Nossal, Figure 1 and section 3.5"
    },
    {
      "Readout": "Agarose-spot entry count",
      "Measured location or object": "Boundary between agarose spot and medium",
      "Reported quantity": "Cells entering beneath a spot",
      "Interpretation limit": "Attractant-containing and attractant-free spots differ in concentration as well as gradient",
      "Primary source": "Szatmary and Nossal, Figure 1 and section 3.5"
    },
    {
      "Readout": "Trajectory directness",
      "Measured location or object": "Individual cell path",
      "Reported quantity": "Euclidean distance divided by accumulated distance",
      "Interpretation limit": "Describes path straightness without identifying migration toward the chemical source",
      "Primary source": "ibidi manual, section 6.1"
    },
    {
      "Readout": "Parallel forward migration index",
      "Measured location or object": "Individual tracks aligned with gradient axis",
      "Reported quantity": "Mean signed gradient-axis displacement divided by each track length",
      "Interpretation limit": "Axis orientation must be defined relative to the gradient; sign depends on coordinate convention",
      "Primary source": "ibidi manual, section 6.3"
    }
  ],
  "sources": [
    {
      "title": "ibidi: Instructions Chemotaxis and Migration Tool 2.0",
      "url": "https://ibidi.com/img/cms/downloads/in/Manual_ChemotaxisTool_2_0_eng.pdf",
      "accessed": "2026-11-16"
    },
    {
      "title": "Prangley et al.: Quantifying Human Monocyte Chemotaxis In Vitro and Murine Lymphocyte Trafficking In Vivo",
      "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC5755269/",
      "accessed": "2026-11-16"
    },
    {
      "title": "Szatmary and Nossal: Determining whether observed eukaryotic cell migration indicates chemotactic responsiveness or random chemokinetic motion",
      "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC5546118/",
      "accessed": "2026-11-16"
    }
  ]
}