{
  "name": "ChIPseeker annotation controls and reporting checks",
  "description": "An original documentation crosswalk linking annotation settings and environment checks to the information an analyst should preserve. Compiled from the ChIPseeker manual and vignette, Bioconductor installation guidance, and the hg19 TxDb package record; not measured experimental results.",
  "page": "https://casrai.org/guides/chipseeker",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-15T11:28:32Z",
  "temporalCoverage": null,
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Control",
      "unit": "",
      "description": ""
    },
    {
      "name": "Documented interface",
      "unit": "",
      "description": ""
    },
    {
      "name": "Documented value or behavior",
      "unit": "",
      "description": ""
    },
    {
      "name": "Reporting check",
      "unit": "",
      "description": ""
    },
    {
      "name": "Source URL",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Control": "TSS annotation window",
      "Documented interface": "tssRegion",
      "Documented value or behavior": "c(-3000, 3000)",
      "Reporting check": "State the selected TSS window; the example uses the documented default.",
      "Source URL": "https://bioconductor.org/packages/release/bioc/manuals/ChIPseeker/man/ChIPseeker.pdf"
    },
    {
      "Control": "Feature assignment order",
      "Documented interface": "genomicAnnotationPriority",
      "Documented value or behavior": "Promoter; 5UTR; 3UTR; Exon; Intron; Downstream; Intergenic",
      "Reporting check": "Retain the priority setting when interpreting single-category summaries.",
      "Source URL": "https://bioconductor.org/packages/release/bioc/manuals/ChIPseeker/man/ChIPseeker.pdf"
    },
    {
      "Control": "Annotation level",
      "Documented interface": "level",
      "Documented value or behavior": "transcript",
      "Reporting check": "Record whether annotation uses the transcript or gene option.",
      "Source URL": "https://bioconductor.org/packages/release/bioc/manuals/ChIPseeker/man/ChIPseeker.pdf"
    },
    {
      "Control": "Transcript reference",
      "Documented interface": "TxDb",
      "Documented value or behavior": "TxDb.Hsapiens.UCSC.hg19.knownGene",
      "Reporting check": "Name the annotation database used by the supplied hg19 example.",
      "Source URL": "https://bioconductor.org/packages/release/data/annotation/html/TxDb.Hsapiens.UCSC.hg19.knownGene.html"
    },
    {
      "Control": "Identifier mapping",
      "Documented interface": "annoDb",
      "Documented value or behavior": "org.Hs.eg.db in the vignette",
      "Reporting check": "Record the mapping package and identifier system before downstream analysis.",
      "Source URL": "https://bioconductor.org/packages/release/bioc/vignettes/ChIPseeker/inst/doc/ChIPseeker.html"
    },
    {
      "Control": "Environment consistency",
      "Documented interface": "BiocManager::valid()",
      "Documented value or behavior": "Flags too-new or outdated packages",
      "Reporting check": "Keep diagnostic output with the analysis environment record.",
      "Source URL": "https://www.bioconductor.org/install/"
    }
  ],
  "sources": [
    {
      "title": "ChIPseeker reference manual",
      "url": "https://bioconductor.org/packages/release/bioc/manuals/ChIPseeker/man/ChIPseeker.pdf",
      "accessed": "2026-11-15"
    },
    {
      "title": "ChIPseeker release vignette",
      "url": "https://bioconductor.org/packages/release/bioc/vignettes/ChIPseeker/inst/doc/ChIPseeker.html",
      "accessed": "2026-11-15"
    },
    {
      "title": "Bioconductor installation",
      "url": "https://www.bioconductor.org/install/",
      "accessed": "2026-11-15"
    },
    {
      "title": "hg19 knownGene TxDb",
      "url": "https://bioconductor.org/packages/release/data/annotation/html/TxDb.Hsapiens.UCSC.hg19.knownGene.html",
      "accessed": "2026-11-15"
    }
  ]
}