  "name": "CoolProp property backends and what the documentation says about each",
  "description": "Compares the five calculation routes documented for CoolProp (HEOS, REFPROP, IF97, INCOMP and tabular interpolation) by fluid-string prefix, coverage and documented speed or installation notes, compiled from the CoolProp project documentation, the 2014 CoolProp paper and the NIST REFPROP page.",
  "page": "https://casrai.org/guides/coolprop",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-15T14:40:00Z",
  "temporalCoverage": "2014/2026",
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Backend",
      "unit": "",
      "description": ""
    },
    {
      "name": "Fluid-string prefix",
      "unit": "",
      "description": ""
    },
    {
      "name": "Coverage as documented",
      "unit": "",
      "description": ""
    },
    {
      "name": "Documented note",
      "unit": "",
      "description": ""
    },
    {
      "name": "Source",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Backend": "HEOS (default)",
      "Fluid-string prefix": "HEOS:: or none",
      "Coverage as documented": "Helmholtz equations of state for pure and pseudo-pure fluids, and mixtures built on Helmholtz formulations",
      "Documented note": "Default backend of PropsSI",
      "Source": "CoolProp high-level API documentation; CoolProp home page"
    },
    {
      "Backend": "REFPROP",
      "Fluid-string prefix": "REFPROP::",
      "Coverage as documented": "Fluids and mixtures available in NIST REFPROP (SRD 23, Version 10: 147 pure fluids, 5 pseudo-pure fluids, mixtures up to 20 components)",
      "Documented note": "REFPROP must be installed on the machine",
      "Source": "CoolProp high-level API documentation; NIST REFPROP page"
    },
    {
      "Backend": "IAPWS-IF97",
      "Fluid-string prefix": "IF97::",
      "Coverage as documented": "Water and steam only",
      "Documented note": "Faster than the default backend, for water only",
      "Source": "CoolProp high-level API documentation"
    },
    {
      "Backend": "Incompressible fluids and brines",
      "Fluid-string prefix": "INCOMP::",
      "Coverage as documented": "Incompressible fluids and brines, for example INCOMP::MEG-20%",
      "Documented note": "Documented in the high-level API as a separate backend",
      "Source": "CoolProp high-level API documentation; CoolProp home page"
    },
    {
      "Backend": "Tabular interpolation (TTSE and bicubic)",
      "Fluid-string prefix": "Not applicable (interpolation of tabulated values)",
      "Coverage as documented": "Speed-oriented interpolation of properties, tested in the 2014 paper on subcooled water and R245fa",
      "Documented note": "TTSE and bicubic more than 120 times faster than direct IAPWS-95 for subcooled water; bicubic generally orders of magnitude more accurate than TTSE for R245fa",
      "Source": "Bell et al. 2014, Ind. Eng. Chem. Res. 53(6), 2498-2508"
    }
  ],
  "sources": [
    {
      "title": "CoolProp project home page",
      "url": "http://www.coolprop.org/",
      "accessed": "2026-11-12"
    },
    {
      "title": "CoolProp high-level API documentation",
      "url": "http://www.coolprop.org/coolprop/HighLevelAPI.html",
      "accessed": "2026-11-12"
    },
    {
      "title": "Bell et al. 2014, CoolProp paper (PubMed Central)",
      "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC3944605",
      "accessed": "2026-11-12"
    },
    {
      "title": "NIST REFPROP, Standard Reference Database 23",
      "url": "https://www.nist.gov/srd/refprop",
      "accessed": "2026-11-12"
    }
  ]
}