  "name": "CytoFLEX and Attune NxT: sourced specifications side by side",
  "description": "Compiled from Beckman Coulter's CytoFLEX LX press release, the University of Copenhagen core facility page for its four-laser CytoFLEX S, and Thermo Fisher's Attune NxT features page and BioProbes 71 article. Each cell is the source's own statement for that model; vendor claims are attributed to the vendor.",
  "page": "https://casrai.org/guides/cytoflex",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-15T07:46:06Z",
  "temporalCoverage": null,
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Attribute",
      "unit": "",
      "description": ""
    },
    {
      "name": "CytoFLEX S (Copenhagen facility)",
      "unit": "",
      "description": ""
    },
    {
      "name": "CytoFLEX LX (Beckman, 2017)",
      "unit": "",
      "description": ""
    },
    {
      "name": "Attune NxT (Thermo Fisher)",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Attribute": "Lasers",
      "CytoFLEX S (Copenhagen facility)": "405 nm 80 mW, 488 nm 50 mW, 561 nm 30 mW, 638 nm 50 mW (solid state)",
      "CytoFLEX LX (Beckman, 2017)": "Excitation from UV 355 nm to infrared 808 nm",
      "Attune NxT (Thermo Fisher)": "Up to 4 flat-top solid-state lasers: 405 nm 50 mW, 488 nm 50 mW, 561 nm 50 mW, 637 nm 100 mW"
    },
    {
      "Attribute": "Detection described",
      "CytoFLEX S (Copenhagen facility)": "APD detectors; facility says unmatched red sensitivity",
      "CytoFLEX LX (Beckman, 2017)": "APDs with quantum efficiency stated as high and stable from 400 to 1100 nm",
      "Attune NxT (Thermo Fisher)": "FSC photodiode; SSC PMT (488/10 band pass)"
    },
    {
      "Attribute": "Parameters",
      "CytoFLEX S (Copenhagen facility)": "13 fluorescence plus FSC and SSC",
      "CytoFLEX LX (Beckman, 2017)": "Parameters can be added by upgrade (Beckman)",
      "Attune NxT (Thermo Fisher)": "Up to 16 (features page); 14 emission channels (BioProbes)"
    },
    {
      "Attribute": "Filters",
      "CytoFLEX S (Copenhagen facility)": "Examples: 525/40, 585/42, 660/10, 450/45",
      "CytoFLEX LX (Beckman, 2017)": "Extensive set of repositionable band pass filters",
      "Attune NxT (Thermo Fisher)": "Keyed, user-changeable filters"
    },
    {
      "Attribute": "Sample focusing",
      "CytoFLEX S (Copenhagen facility)": "Not stated by the source",
      "CytoFLEX LX (Beckman, 2017)": "Not stated by the source",
      "Attune NxT (Thermo Fisher)": "Acoustic focusing: ultrasonic waves plus hydrodynamic forces; 12.5 to 1,000 uL/min (Thermo)"
    },
    {
      "Attribute": "Volumetric counting",
      "CytoFLEX S (Copenhagen facility)": "Not stated by the source",
      "CytoFLEX LX (Beckman, 2017)": "Not stated by the source",
      "Attune NxT (Thermo Fisher)": "Positive-displacement syringe pump gives volumetric counts (Thermo)"
    },
    {
      "Attribute": "Sample formats",
      "CytoFLEX S (Copenhagen facility)": "5 mL (12 x 75 mm) or 1.2 mL tubes; optional plate loader",
      "CytoFLEX LX (Beckman, 2017)": "Not stated by the source",
      "Attune NxT (Thermo Fisher)": "Tubes 17 x 100 to 8.5 x 45 mm; optional autosampler up to 384 samples"
    },
    {
      "Attribute": "Stated resolution or sensitivity",
      "CytoFLEX S (Copenhagen facility)": "Particles under 300 nm (488 nm SSC), under 80 nm polystyrene (405 nm SSC); rCV 3%",
      "CytoFLEX LX (Beckman, 2017)": "Qualitative only (no numbers given)",
      "Attune NxT (Thermo Fisher)": "Fluorescence resolution CV under 3%; predicted MESF 80 FITC, 30 PE, 70 APC or lower"
    },
    {
      "Attribute": "Use status",
      "CytoFLEX S (Copenhagen facility)": "Not stated by the source",
      "CytoFLEX LX (Beckman, 2017)": "Not stated by the source",
      "Attune NxT (Thermo Fisher)": "Research use only (BioProbes)"
    }
  ],
  "sources": [
    {
      "title": "Beckman Coulter, CytoFLEX LX press release",
      "url": "https://www.beckman.com/news/cytoflex-lx-uv-press-release",
      "accessed": "2026-11-15"
    },
    {
      "title": "University of Copenhagen FCSC, CytoFLEX S (4-laser)",
      "url": "https://www.fcsc.ku.dk/equipment/flow-cytometers/cytoflex/",
      "accessed": "2026-11-15"
    },
    {
      "title": "Thermo Fisher, Attune NxT features",
      "url": "https://www.thermofisher.com/us/en/home/life-science/cell-analysis/flow-cytometry/flow-cytometers/attune-nxt-flow-cytometer/features",
      "accessed": "2026-11-15"
    },
    {
      "title": "Thermo Fisher, BioProbes 71, The Attune NxT Acoustic Focusing Cytometer",
      "url": "https://www.thermofisher.cn/cn/en/home/references/newsletters-and-journals/bioprobes-journal-of-cell-biology-applications/bioprobes-71/bioprobes-71-attune-nxt-cytometer.html",
      "accessed": "2026-11-15"
    }
  ]
}