  "name": "Federal provisions governing an NPDES discharge monitoring report",
  "description": "A cross-walk of the federal regulations that govern DMRs, compiled from the text of 40 CFR 122.41, 122.22, 122.48 and 127.16, giving for each provision what it requires and which step of the sample-to-DMR route it affects.",
  "page": "https://casrai.org/guides/discharge-monitoring-report",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-19T08:33:43Z",
  "temporalCoverage": null,
  "spatialCoverage": "United States",
  "columns": [
    {
      "name": "Provision",
      "unit": "",
      "description": ""
    },
    {
      "name": "What it requires",
      "unit": "",
      "description": ""
    },
    {
      "name": "Step it affects",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Provision": "40 CFR 122.41(j)(1)",
      "What it requires": "Samples and measurements must be representative of the monitored activity",
      "Step it affects": "Sampling"
    },
    {
      "Provision": "40 CFR 122.41(j)(2)",
      "What it requires": "Keep monitoring information including calibration and maintenance records, reports and application data at least 3 years (sewage sludge records at least 5 years)",
      "Step it affects": "Record retention"
    },
    {
      "Provision": "40 CFR 122.41(j)(3)",
      "What it requires": "Records include date, exact place and time of sampling; sampler; analysis dates; analyst; methods; results",
      "Step it affects": "Record content"
    },
    {
      "Provision": "40 CFR 122.41(j)(4)",
      "What it requires": "Monitoring conducted according to test procedures under 40 CFR Part 136",
      "Step it affects": "Analysis"
    },
    {
      "Provision": "40 CFR 122.41(l)(4)",
      "What it requires": "Report monitoring results on a DMR at the permit's intervals; electronic from 21 December 2016; extra approved-method results are included",
      "Step it affects": "Reporting"
    },
    {
      "Provision": "40 CFR 122.22",
      "What it requires": "Reports signed by a signatory or duly authorized representative with a certification under penalty of law",
      "Step it affects": "Certification"
    },
    {
      "Provision": "40 CFR 122.48",
      "What it requires": "Permit must specify monitoring type, intervals and frequency sufficient to yield data, and reporting frequency",
      "Step it affects": "Permit design"
    },
    {
      "Provision": "40 CFR 127.16 Table 1",
      "What it requires": "DMR electronic reporting compliance date 21 December 2016; other listed reports 21 December 2025",
      "Step it affects": "Electronic submission"
    }
  ],
  "sources": [
    {
      "title": "40 CFR 122.41",
      "url": "https://www.law.cornell.edu/cfr/text/40/122.41",
      "accessed": "2026-11-19"
    },
    {
      "title": "40 CFR 122.22",
      "url": "https://www.law.cornell.edu/cfr/text/40/122.22",
      "accessed": "2026-11-19"
    },
    {
      "title": "40 CFR 122.48",
      "url": "https://www.law.cornell.edu/cfr/text/40/122.48",
      "accessed": "2026-11-19"
    },
    {
      "title": "40 CFR 127.16",
      "url": "https://www.law.cornell.edu/cfr/text/40/127.16",
      "accessed": "2026-11-19"
    }
  ]
}