  "name": "OECD guidelines for the Draize eye and skin tests and their in vitro counterparts",
  "description": "Cross-walk of the OECD test guidelines that codify the rabbit eye and skin irritation tests and the in vitro guidelines that address the same endpoints, compiled from OECD TG 405 (2002), OECD TG 439 (2013), the NICEATM/ICCVAM ocular in vitro page and a 2025 history review. Each adoption detail is stated only as given in the source named in the last column.",
  "page": "https://casrai.org/guides/draize-test",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-19T10:45:00Z",
  "temporalCoverage": null,
  "spatialCoverage": null,
  "columns": [
    {
      "name": "OECD guideline",
      "unit": "",
      "description": ""
    },
    {
      "name": "Endpoint",
      "unit": "",
      "description": ""
    },
    {
      "name": "Test system",
      "unit": "",
      "description": ""
    },
    {
      "name": "Adoption detail given in source",
      "unit": "",
      "description": ""
    },
    {
      "name": "Source",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "OECD guideline": "TG 405",
      "Endpoint": "Acute eye irritation/corrosion",
      "Test system": "In vivo, albino rabbit (preferred)",
      "Adoption detail given in source": "Adopted 1981, revised 1987; 24 April 2002 edition read",
      "Source": "OECD TG 405"
    },
    {
      "OECD guideline": "TG 404",
      "Endpoint": "Acute dermal irritation/corrosion",
      "Test system": "In vivo, rabbit skin",
      "Adoption detail given in source": "Adopted 1981, revised 1992 and 2002",
      "Source": "OECD TG 439"
    },
    {
      "OECD guideline": "TG 437",
      "Endpoint": "Eye: corrosives and severe irritants (BCOP)",
      "Test system": "Bovine corneal opacity and permeability test",
      "Adoption detail given in source": "Adopted September 2009, revised 2013 and updated 2025",
      "Source": "NICEATM/ICCVAM"
    },
    {
      "OECD guideline": "TG 438",
      "Endpoint": "Eye: corrosives and severe irritants (ICE)",
      "Test system": "Isolated chicken eye test",
      "Adoption detail given in source": "Adopted September 2009, revised 2013 and updated 2025",
      "Source": "NICEATM/ICCVAM"
    },
    {
      "OECD guideline": "TG 491",
      "Endpoint": "Eye irritation (short time exposure)",
      "Test system": "Short time exposure test",
      "Adoption detail given in source": "Listed for 2015",
      "Source": "2025 history review"
    },
    {
      "OECD guideline": "TG 492",
      "Endpoint": "Eye irritation",
      "Test system": "Reconstructed human cornea-like epithelium",
      "Adoption detail given in source": "EpiOcular test method listed for 2017; TG 492B listed for 2024",
      "Source": "2025 history review"
    },
    {
      "OECD guideline": "TG 494",
      "Endpoint": "Eye irritation",
      "Test system": "Vitrigel-Eye",
      "Adoption detail given in source": "Listed in the review's table of non-animal guidelines",
      "Source": "2025 history review"
    },
    {
      "OECD guideline": "TG 439",
      "Endpoint": "Skin irritation (GHS Category 2)",
      "Test system": "Reconstructed human epidermis, MTT viability",
      "Adoption detail given in source": "Adopted 26 July 2013 (version read)",
      "Source": "OECD TG 439"
    },
    {
      "OECD guideline": "TG 430, 431, 435",
      "Endpoint": "Skin corrosion",
      "Test system": "In vitro corrosivity methods; TG 431 uses the same RhE system with a different protocol",
      "Adoption detail given in source": "Named in TG 439 as the corrosivity guidelines",
      "Source": "OECD TG 439"
    }
  ],
  "sources": [
    {
      "title": "OECD Test No. 405: Acute Eye Irritation/Corrosion (2002)",
      "url": "https://www.enfo.hu/sites/default/files/OECDtg405.pdf",
      "accessed": "2026-11-14"
    },
    {
      "title": "OECD Test No. 439: In Vitro Skin Irritation (2013)",
      "url": "https://ntp.niehs.nih.gov/sites/default/files/iccvam/suppdocs/feddocs/oecd/oecd-tg439-2013-508.pdf",
      "accessed": "2026-11-14"
    },
    {
      "title": "NICEATM/ICCVAM: In vitro ocular test methods",
      "url": "https://ntp.niehs.nih.gov/whatwestudy/niceatm/test-method-evaluations/ocular/in-vitro",
      "accessed": "2026-11-14"
    },
    {
      "title": "History of OECD test guidelines for non-animal tests, Genes and Environment (2025)",
      "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC11781050/",
      "accessed": "2026-11-14"
    }
  ]
}