  "name": "Dry ice (solid carbon dioxide) SDS comparison: Linde US 2022, Linde Malaysia 2023, Flinn MSDS 2010",
  "description": "Side-by-side comparison of what three published safety data sheets for solid carbon dioxide say about format, classification, exposure limits, incompatibles, storage and disposal. Compiled by CASRAI from the three sheets listed as sources, each read in full text; cells restate the sheet wording in shortened form.",
  "page": "https://casrai.org/guides/dry-ice-sds",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-28T08:20:00Z",
  "temporalCoverage": "Sheet revisions 2010, 2022 and 2023",
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Attribute",
      "unit": "",
      "description": ""
    },
    {
      "name": "Linde US P-4575 (rev 05/23/2022)",
      "unit": "",
      "description": ""
    },
    {
      "name": "Linde Malaysia (rev 03/04/2023)",
      "unit": "",
      "description": ""
    },
    {
      "name": "Flinn MSDS 212.50 (rev 09/27/2010)",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Attribute": "Regulatory format",
      "Linde US P-4575 (rev 05/23/2022)": "States conformity to 29 CFR 1910.1200 (US Hazard Communication)",
      "Linde Malaysia (rev 03/04/2023)": "Industry Code of Practice on chemicals classification and hazard communication (2014)",
      "Flinn MSDS 212.50 (rev 09/27/2010)": "Older MSDS layout; no regulation cited in the text read"
    },
    {
      "Attribute": "Section 2 classification and hazard wording",
      "Linde US P-4575 (rev 05/23/2022)": "Hazard statements: may cause frostbite; cryogenic burns or injury; may increase respiration and heart rate; vapour may displace oxygen and cause rapid suffocation",
      "Linde Malaysia (rev 03/04/2023)": "Not classified; other hazards: none",
      "Flinn MSDS 212.50 (rev 09/27/2010)": "NFPA-style Health 0, Flammability 0, Reactivity 0; text says skin contact may cause frostbite and blisters"
    },
    {
      "Attribute": "8-hour TWA exposure limit",
      "Linde US P-4575 (rev 05/23/2022)": "5000 ppm (ACGIH, OSHA PEL)",
      "Linde Malaysia (rev 03/04/2023)": "5000 ppm (Malaysia, Germany, UK, ACGIH, New Zealand)",
      "Flinn MSDS 212.50 (rev 09/27/2010)": "5000 ppm"
    },
    {
      "Attribute": "Short-term exposure limit",
      "Linde US P-4575 (rev 05/23/2022)": "30000 ppm (ACGIH)",
      "Linde Malaysia (rev 03/04/2023)": "15000 ppm (UK WEL); 30000 ppm (New Zealand, ACGIH)",
      "Flinn MSDS 212.50 (rev 09/27/2010)": "3000 ppm as printed (conflicts with 30000 ppm elsewhere)"
    },
    {
      "Attribute": "Incompatible materials",
      "Linde US P-4575 (rev 05/23/2022)": "Alkali metals, alkaline earth metals, acetylide-forming metals, chromium, titanium above 550 C, uranium above 750 C, magnesium above 775 C",
      "Linde Malaysia (rev 03/04/2023)": "None; refers to ISO 11114",
      "Flinn MSDS 212.50 (rev 09/27/2010)": "No list; notes dusts of various metals are ignitable and explosive when suspended in carbon dioxide"
    },
    {
      "Attribute": "Storage wording",
      "Linde US P-4575 (rev 05/23/2022)": "Insulated containers opening from the top; loose lids; ventilation at floor or below-grade level",
      "Linde Malaysia (rev 03/04/2023)": "Compressed-gas container wording: valve guards, upright and secured, below 50 C, well ventilated",
      "Flinn MSDS 212.50 (rev 09/27/2010)": "Vented cooler in a well-ventilated area"
    },
    {
      "Attribute": "Hand and eye protection",
      "Linde US P-4575 (rev 05/23/2022)": "Cold-insulating gloves; safety glasses with side shields; tongs or insulated gloves for handling",
      "Linde Malaysia (rev 03/04/2023)": "Working gloves, EN 388 level 1 or higher; safety glasses with side shields (EN 166)",
      "Flinn MSDS 212.50 (rev 09/27/2010)": "Chemical splash goggles, chemical-resistant gloves, chemical-resistant apron"
    },
    {
      "Attribute": "Disposal wording",
      "Linde US P-4575 (rev 05/23/2022)": "In accordance with container supplier or owner instructions",
      "Linde Malaysia (rev 03/04/2023)": "Contact supplier; return unused product in original container; avoid large discharge to atmosphere",
      "Flinn MSDS 212.50 (rev 09/27/2010)": "Place in an open container in a fume hood or outdoors and allow to sublimate"
    }
  ],
  "sources": [
    {
      "title": "Linde US: Carbon Dioxide, Solid or Dry Ice, SDS P-4575 (University of Iowa Biochemistry Stores copy)",
      "url": "https://biochemstores.medicine.uiowa.edu/sites/biochemstores.medicine.uiowa.edu/files/2023-11/dry-ice-ultraice-co2-safety-data-sheet-sds-p4575_v2.pdf",
      "accessed": "2026-11-17"
    },
    {
      "title": "Linde Malaysia: Carbon dioxide, solid (Dry ice) SDS",
      "url": "https://static.prd.echannel.linde.com/wcsstore/MY_RSE_Industrial_Ntl_Store/HCL%20-%20Images/MSDS/Dry%20Ice/Carbon%20dioxide,%20solid%20(Dry%20ice)_EN.pdf",
      "accessed": "2026-11-17"
    },
    {
      "title": "Flinn Scientific: Carbon Dioxide, Solid, MSDS 212.50 (NISE Network copy)",
      "url": "https://www.nisenet.org/sites/default/files/sds212.5_carbon_dioxide_solid.pdf",
      "accessed": "2026-11-17"
    }
  ]
}