  "name": "Dry Room Environmental and Cleanliness Parameters by Battery Manufacturing Process Zone",
  "description": "Original compilation comparing target dew points, absolute moisture content, relative humidity at 20°C, ISO 14644-1 particulate cleanliness classes, and primary dehumidification technologies across key battery energy storage manufacturing and assembly zones. Compiled from Argonne National Laboratory process modeling (Ahmed et al., 2016), ORNL Battery Manufacturing Facility specifications, and industrial desiccant standards (Munters, Vaisala).",
  "page": "https://casrai.org/guides/dry-room",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-15T14:47:28Z",
  "temporalCoverage": "2016/2026",
  "spatialCoverage": "Global",
  "columns": [
    {
      "name": "Process Zone",
      "unit": "",
      "description": "Battery production stage or cell fabrication operation"
    },
    {
      "name": "Target Dew Point",
      "unit": "°C",
      "description": "Maximum allowable atmospheric dew point temperature"
    },
    {
      "name": "Relative Humidity at 20°C",
      "unit": "%",
      "description": "Equivalent relative humidity at standard 20°C room temperature"
    },
    {
      "name": "Moisture Concentration",
      "unit": "ppmv",
      "description": "Atmospheric moisture volume fraction"
    },
    {
      "name": "Cleanroom Classification",
      "unit": "",
      "description": "Airborne particulate cleanliness limit per ISO 14644-1"
    },
    {
      "name": "Primary Dehumidification Technology",
      "unit": "",
      "description": "HVAC adsorption and filtration technology deployed"
    }
  ],
  "rows": [
    {
      "Process Zone": "Active Material Storage & Anode Preparation",
      "Target Dew Point": -20,
      "Relative Humidity at 20°C": 1.05,
      "Moisture Concentration": 1025,
      "Cleanroom Classification": "ISO Class 8",
      "Primary Dehumidification Technology": "Single-rotor silica gel desiccant wheel with chilled-water pre-cooling"
    },
    {
      "Process Zone": "Cathode Slurry Preparation & Coating",
      "Target Dew Point": -30,
      "Relative Humidity at 20°C": 0.38,
      "Moisture Concentration": 375,
      "Cleanroom Classification": "ISO Class 8",
      "Primary Dehumidification Technology": "High-capacity silica gel desiccant wheel with solvent exhaust purge"
    },
    {
      "Process Zone": "Electrode Slitting & Calendering",
      "Target Dew Point": -35,
      "Relative Humidity at 20°C": 0.22,
      "Moisture Concentration": 220,
      "Cleanroom Classification": "ISO Class 7",
      "Primary Dehumidification Technology": "Dual-rotor desiccant system with HEPA filtration (H14)"
    },
    {
      "Process Zone": "Electrode Winding & Z-Fold Stacking",
      "Target Dew Point": -40,
      "Relative Humidity at 20°C": 0.12,
      "Moisture Concentration": 127,
      "Cleanroom Classification": "ISO Class 7",
      "Primary Dehumidification Technology": "Dual-rotor silica gel and molecular sieve with laminar air distribution"
    },
    {
      "Process Zone": "Electrolyte Preparation & Injection",
      "Target Dew Point": -45,
      "Relative Humidity at 20°C": 0.07,
      "Moisture Concentration": 72,
      "Cleanroom Classification": "ISO Class 6",
      "Primary Dehumidification Technology": "Dual-stage desiccant with deep chilled brine pre-cooling (-5°C) and HEPA"
    },
    {
      "Process Zone": "Cell Sealing & Vacuum Packaging",
      "Target Dew Point": -50,
      "Relative Humidity at 20°C": 0.038,
      "Moisture Concentration": 39,
      "Cleanroom Classification": "ISO Class 6",
      "Primary Dehumidification Technology": "Molecular sieve desiccant rotor with nitrogen purge and positive pressure (+40 Pa)"
    },
    {
      "Process Zone": "Lithium Metal Anode Handling & Assembly",
      "Target Dew Point": -60,
      "Relative Humidity at 20°C": 0.011,
      "Moisture Concentration": 10.7,
      "Cleanroom Classification": "ISO Class 6",
      "Primary Dehumidification Technology": "Ultra-low dew point molecular sieve rotor with Green PowerPurge heat recovery"
    },
    {
      "Process Zone": "Sulfide-Based Solid-State Cell Fabrication",
      "Target Dew Point": -70,
      "Relative Humidity at 20°C": 0.0026,
      "Moisture Concentration": 2.6,
      "Cleanroom Classification": "ISO Class 5/6",
      "Primary Dehumidification Technology": "Multi-stage cryogenic condensation and synthetic zeolite adsorption with H2S scrubbing"
    }
  ],
  "sources": [
    {
      "title": "Study of a dry room in a battery manufacturing plant using a process model (Ahmed et al., 2016)",
      "url": "https://doi.org/10.1016/j.jpowsour.2016.06.107",
      "accessed": "2026-11-15"
    },
    {
      "title": "Oak Ridge National Laboratory Battery Manufacturing Facility Specifications",
      "url": "https://www.ornl.gov/facility/bmf",
      "accessed": "2026-11-15"
    },
    {
      "title": "ASHRAE Handbook: HVAC Applications - Clean Spaces and Industrial Moisture Control",
      "url": "https://www.ashrae.org/technical-resources/ashrae-handbook",
      "accessed": "2026-11-15"
    },
    {
      "title": "Vaisala Dew Point and Moisture Measurement in Battery Manufacturing",
      "url": "https://www.vaisala.com/en/industries/battery-manufacturing",
      "accessed": "2026-11-15"
    },
    {
      "title": "Munters Dry Room Dehumidification Solutions for Lithium-Ion Battery Production",
      "url": "https://www.munters.com/en/solutions/dry-rooms-for-lithium-battery-production/",
      "accessed": "2026-11-15"
    }
  ]
}