  "name": "ENVI-met simulation modules, what each calculates and stated limits",
  "description": "A module-by-module summary of the ENVI-met microclimate model compiled from the developer's model architecture documentation (envi-met.info) and the vendor website: the model area, what each module calculates and the limits or edition notes the documentation states.",
  "page": "https://casrai.org/guides/envi-met",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-20T20:48:54Z",
  "temporalCoverage": "2023/2026",
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Module",
      "unit": "",
      "description": ""
    },
    {
      "name": "Model area",
      "unit": "",
      "description": ""
    },
    {
      "name": "What it calculates",
      "unit": "",
      "description": ""
    },
    {
      "name": "Stated limit or edition note",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Module": "Wind field",
      "Model area": "Atmosphere",
      "What it calculates": "3D CFD: Reynolds-averaged non-hydrostatic Navier-Stokes per grid cell and time step; vegetation as drag forces",
      "Stated limit or edition note": "Real-time flow option needs very small time steps and very powerful computers"
    },
    {
      "Module": "Turbulence",
      "Model area": "Atmosphere",
      "What it calculates": "E-epsilon 1.5-order closure with two prognostic equations",
      "Stated limit or edition note": "First-order mixing-length model available for low wind"
    },
    {
      "Module": "Radiation",
      "Model area": "Atmosphere",
      "What it calculates": "Shortwave and longwave fluxes with shading, reflection and vegetation effects",
      "Stated limit or edition note": "IVS method described for the Expert version"
    },
    {
      "Module": "Air temperature and humidity",
      "Model area": "Atmosphere",
      "What it calculates": "Sources and sinks of sensible heat and vapour with advection and diffusion",
      "Stated limit or edition note": "Walls and roofs can act as humidity sources if greened"
    },
    {
      "Module": "Pollutant dispersion",
      "Model area": "Atmosphere",
      "What it calculates": "Up to 6 pollutants: particles, passive gases, reactive NO-NO2-O3 cycle",
      "Stated limit or edition note": "Photocatalytic surface effects in the Expert version"
    },
    {
      "Module": "Surface and soil temperature",
      "Model area": "Soil",
      "What it calculates": "Natural soils and sealing materials down to 4 m depth; conductivity depends on soil water",
      "Stated limit or edition note": "One soil or sealing material per vertical layer"
    },
    {
      "Module": "Soil water content",
      "Model area": "Soil",
      "What it calculates": "Soil hydraulic state from Darcy's law with evaporation, water exchange and root uptake",
      "Stated limit or edition note": "Complex irrigation and subsurface water in the consulting version"
    },
    {
      "Module": "Water bodies",
      "Model area": "Soil",
      "What it calculates": "Special soil type with shortwave transmission and absorption in the water",
      "Stated limit or edition note": "Still waters only; no turbulent mixing; no second energy balance at the pool floor"
    },
    {
      "Module": "3D vegetation",
      "Model area": "Vegetation",
      "What it calculates": "Individual species with water balance, heat and water stress, leaf energy balance, stomata response",
      "Stated limit or edition note": "Tree growing-condition matching and wind-risk assessment are consulting-only"
    },
    {
      "Module": "Building surfaces",
      "Model area": "Built environment",
      "What it calculates": "Each wall and roof segment: 7 calculation nodes, up to 3 material layers",
      "Stated limit or edition note": "Curved or inclined surfaces approximated on a rectangular grid"
    },
    {
      "Module": "Building energy",
      "Model area": "Built environment",
      "What it calculates": "Indoor temperature calculated in parallel with the outdoor simulation, with an initial zoning model",
      "Stated limit or edition note": "None stated beyond the zoning model being initial"
    },
    {
      "Module": "Thermal comfort indices",
      "Model area": "Output",
      "What it calculates": "Mean Radiant Temperature, PMV/PPD, PET and UTCI via BioMet",
      "Stated limit or edition note": "SET* appears in the vendor feature list"
    }
  ],
  "sources": [
    {
      "title": "ENVI-met Model Architecture",
      "url": "https://envi-met.info/doku.php?id=intro:modelconept",
      "accessed": "2026-11-20"
    },
    {
      "title": "ENVI-met GmbH official website",
      "url": "https://envi-met.com/",
      "accessed": "2026-11-20"
    }
  ]
}