  "name": "Class C versus Class F fly ash: effects on concrete properties and dosage",
  "description": "Property-by-property comparison of Class C and Class F coal fly ash substituted for portland cement, compiled from the FHWA supplementary cementitious materials tech brief (2016) and the FHWA coal fly ash user guideline (1997) and Materials Note 51.",
  "page": "https://casrai.org/guides/fly-ash-concrete",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-27T11:55:00Z",
  "temporalCoverage": "1997/2016",
  "spatialCoverage": "United States",
  "columns": [
    {
      "name": "Property",
      "unit": "",
      "description": ""
    },
    {
      "name": "Class C fly ash",
      "unit": "",
      "description": ""
    },
    {
      "name": "Class F fly ash",
      "unit": "",
      "description": ""
    },
    {
      "name": "Source",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Property": "Sum of oxides (SiO2 + Al2O3 + Fe2O3), minimum",
      "Class C fly ash": "50% or more; predominantly hydraulic with some pozzolanic properties",
      "Class F fly ash": "70% or more; pozzolanic",
      "Source": "FHWA-HIF-16-001"
    },
    {
      "Property": "Typical coal source",
      "Class C fly ash": "Usually lignite or subbituminous",
      "Class F fly ash": "Usually anthracite or bituminous",
      "Source": "FHWA-RD-97-148"
    },
    {
      "Property": "Typical share of total cementitious material by weight",
      "Class C fly ash": "20 to 35 percent",
      "Class F fly ash": "15 to 25 percent",
      "Source": "FHWA-RD-97-148"
    },
    {
      "Property": "Usual substitution ratio for removed cement",
      "Class C fly ash": "1:1",
      "Class F fly ash": "1:1, sometimes 1.25:1 or 1.5:1",
      "Source": "FHWA-RD-97-148"
    },
    {
      "Property": "Initial set",
      "Class C fly ash": "Delayed (some sources have little effect)",
      "Class F fly ash": "Delayed",
      "Source": "FHWA-HIF-16-001; FHWA-RD-97-148"
    },
    {
      "Property": "Rate of strength gain",
      "Class C fly ash": "Same or higher",
      "Class F fly ash": "Slower",
      "Source": "FHWA-HIF-16-001"
    },
    {
      "Property": "Heat of hydration",
      "Class C fly ash": "Lower",
      "Class F fly ash": "Significantly lower",
      "Source": "FHWA-HIF-16-001"
    },
    {
      "Property": "Early strength (3-7 days)",
      "Class C fly ash": "Higher",
      "Class F fly ash": "Lower",
      "Source": "FHWA-HIF-16-001"
    },
    {
      "Property": "Late strength (28-56 days)",
      "Class C fly ash": "Same or higher",
      "Class F fly ash": "Same or higher",
      "Source": "FHWA-HIF-16-001"
    },
    {
      "Property": "ASR mitigation",
      "Class C fly ash": "Only at high replacements (e.g. 35 to 45 percent)",
      "Class F fly ash": "Significant above the pessimum replacement level",
      "Source": "FHWA-HIF-16-001"
    },
    {
      "Property": "Sulfate resistance",
      "Class C fly ash": "Must be tested for each ash",
      "Class F fly ash": "Generally improved",
      "Source": "FHWA-RD-97-148"
    }
  ],
  "sources": [
    {
      "title": "FHWA-HIF-16-001 Supplementary Cementitious Materials tech brief",
      "url": "https://www.fhwa.dot.gov/pavement/concrete/pubs/hif16001.pdf",
      "accessed": "2026-11-20"
    },
    {
      "title": "FHWA-RD-97-148 User Guideline, Coal Fly Ash, Portland Cement Concrete",
      "url": "https://www.fhwa.dot.gov/publications/research/infrastructure/structures/97148/cfa53.cfm",
      "accessed": "2026-11-20"
    },
    {
      "title": "FHWA Materials Note 51",
      "url": "https://www.fhwa.dot.gov/Pavement/materials/matnote51.cfm",
      "accessed": "2026-11-20"
    }
  ]
}