  "name": "Inhalation acute toxicity categories 1-4: OSHA cut-offs, point estimates and GHS hazard statements",
  "description": "Compares the four inhalation acute-toxicity categories of the GHS as adopted in 29 CFR 1910.1200 Appendix A (Table A.1.1 upper limits and Table A.1.2 mixture point estimates, based on 4-hour exposures) with the matching hazard statement and signal word from the PubChem GHS Rev. 11 (2025) summary. Compiled from the regulation text and the PubChem table.",
  "page": "https://casrai.org/guides/h330",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-27T12:40:00Z",
  "temporalCoverage": "2025/2026",
  "spatialCoverage": "United States (OSHA HazCom); UN GHS Rev. 11",
  "columns": [
    {
      "name": "Category",
      "unit": "",
      "description": ""
    },
    {
      "name": "Hazard statement",
      "unit": "",
      "description": ""
    },
    {
      "name": "Signal word",
      "unit": "",
      "description": ""
    },
    {
      "name": "Gas upper limit (ppmV)",
      "unit": "ppmV",
      "description": ""
    },
    {
      "name": "Vapor upper limit (mg/l)",
      "unit": "mg/l",
      "description": ""
    },
    {
      "name": "Dust/mist upper limit (mg/l)",
      "unit": "mg/l",
      "description": ""
    },
    {
      "name": "Gas point estimate (ppmV)",
      "unit": "ppmV",
      "description": ""
    },
    {
      "name": "Vapor point estimate (mg/l)",
      "unit": "mg/l",
      "description": ""
    },
    {
      "name": "Dust/mist point estimate (mg/l)",
      "unit": "mg/l",
      "description": ""
    }
  ],
  "rows": [
    {
      "Category": "Category 1",
      "Hazard statement": "H330",
      "Signal word": "Danger",
      "Gas upper limit (ppmV)": 100,
      "Vapor upper limit (mg/l)": 0.5,
      "Dust/mist upper limit (mg/l)": 0.05,
      "Gas point estimate (ppmV)": 10,
      "Vapor point estimate (mg/l)": 0.05,
      "Dust/mist point estimate (mg/l)": 0.005
    },
    {
      "Category": "Category 2",
      "Hazard statement": "H330",
      "Signal word": "Danger",
      "Gas upper limit (ppmV)": 500,
      "Vapor upper limit (mg/l)": 2,
      "Dust/mist upper limit (mg/l)": 0.5,
      "Gas point estimate (ppmV)": 100,
      "Vapor point estimate (mg/l)": 0.5,
      "Dust/mist point estimate (mg/l)": 0.05
    },
    {
      "Category": "Category 3",
      "Hazard statement": "H331",
      "Signal word": "Danger",
      "Gas upper limit (ppmV)": 2500,
      "Vapor upper limit (mg/l)": 10,
      "Dust/mist upper limit (mg/l)": 1,
      "Gas point estimate (ppmV)": 700,
      "Vapor point estimate (mg/l)": 3,
      "Dust/mist point estimate (mg/l)": 0.5
    },
    {
      "Category": "Category 4",
      "Hazard statement": "H332",
      "Signal word": "Warning",
      "Gas upper limit (ppmV)": 20000,
      "Vapor upper limit (mg/l)": 20,
      "Dust/mist upper limit (mg/l)": 5,
      "Gas point estimate (ppmV)": 4500,
      "Vapor point estimate (mg/l)": 11,
      "Dust/mist point estimate (mg/l)": 1.5
    }
  ],
  "sources": [
    {
      "title": "29 CFR 1910.1200 Hazard communication, Appendix A.1 (Cornell LII)",
      "url": "https://www.law.cornell.edu/cfr/text/29/1910.1200",
      "accessed": "2026-11-21"
    },
    {
      "title": "PubChem GHS Classification (Rev. 11, 2025) Summary",
      "url": "https://pubchem.ncbi.nlm.nih.gov/ghs/",
      "accessed": "2026-11-21"
    }
  ]
}