  "name": "HAZOP guide words in IEC 61882:2016, with table and generic meaning",
  "description": "All eleven example guide words in IEC 61882:2016 (Edition 2.0, 2016): the seven basic guide words of Table 1 and the four time and sequence guide words of Table 2, each with the generic meaning the standard assigns and the kind of deviation it prompts. Compiled from the standard's published catalogue text; the standard says additional guide words may be used if defined before examination begins.",
  "page": "https://casrai.org/guides/hazop-study",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-20T19:34:17Z",
  "temporalCoverage": "2016 edition",
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Guide word",
      "unit": "",
      "description": ""
    },
    {
      "name": "IEC 61882:2016 table",
      "unit": "",
      "description": ""
    },
    {
      "name": "Generic meaning (IEC 61882)",
      "unit": "",
      "description": ""
    },
    {
      "name": "Aspect of deviation",
      "unit": "",
      "description": "Editorial grouping based on the standard's table headings: basic, clock time, or order/sequence"
    }
  ],
  "rows": [
    {
      "Guide word": "NO OR NOT",
      "IEC 61882:2016 table": "Table 1",
      "Generic meaning (IEC 61882)": "Complete negation of the design intent",
      "Aspect of deviation": "Basic"
    },
    {
      "Guide word": "MORE",
      "IEC 61882:2016 table": "Table 1",
      "Generic meaning (IEC 61882)": "Quantitative increase",
      "Aspect of deviation": "Basic"
    },
    {
      "Guide word": "LESS",
      "IEC 61882:2016 table": "Table 1",
      "Generic meaning (IEC 61882)": "Quantitative decrease",
      "Aspect of deviation": "Basic"
    },
    {
      "Guide word": "AS WELL AS",
      "IEC 61882:2016 table": "Table 1",
      "Generic meaning (IEC 61882)": "Qualitative modification/increase",
      "Aspect of deviation": "Basic"
    },
    {
      "Guide word": "PART OF",
      "IEC 61882:2016 table": "Table 1",
      "Generic meaning (IEC 61882)": "Qualitative modification/decrease",
      "Aspect of deviation": "Basic"
    },
    {
      "Guide word": "REVERSE",
      "IEC 61882:2016 table": "Table 1",
      "Generic meaning (IEC 61882)": "Logical opposite of the design intent",
      "Aspect of deviation": "Basic"
    },
    {
      "Guide word": "OTHER THAN",
      "IEC 61882:2016 table": "Table 1",
      "Generic meaning (IEC 61882)": "Complete substitution",
      "Aspect of deviation": "Basic"
    },
    {
      "Guide word": "EARLY",
      "IEC 61882:2016 table": "Table 2",
      "Generic meaning (IEC 61882)": "Relative to the clock time",
      "Aspect of deviation": "Clock time"
    },
    {
      "Guide word": "LATE",
      "IEC 61882:2016 table": "Table 2",
      "Generic meaning (IEC 61882)": "Relative to the clock time",
      "Aspect of deviation": "Clock time"
    },
    {
      "Guide word": "BEFORE",
      "IEC 61882:2016 table": "Table 2",
      "Generic meaning (IEC 61882)": "Relating to order or sequence",
      "Aspect of deviation": "Order or sequence"
    },
    {
      "Guide word": "AFTER",
      "IEC 61882:2016 table": "Table 2",
      "Generic meaning (IEC 61882)": "Relating to order or sequence",
      "Aspect of deviation": "Order or sequence"
    }
  ],
  "sources": [
    {
      "title": "IEC 61882:2016 Hazard and operability studies (HAZOP studies) - Application guide (catalogue preview)",
      "url": "https://standards.iteh.ai/catalog/standards/iec/a77032db-bbf0-4270-9eb3-4ee5863317ee/iec-61882-2016",
      "accessed": "2026-11-20"
    }
  ]
}