  "name": "Alternative test methods on the NTP accepted-methods list: OECD Test Guideline and first-listed year (selected entries)",
  "description": "Selected entries compiled from the NIEHS National Toxicology Program Accepted Alternative Methods page, read 2026-11-21. Each row gives the method as named on that page, its toxicity area, the OECD Test Guideline number and the year listed for that guideline. Entries were chosen to show older single-endpoint in vitro replacements next to newer defined approaches; later update years shown on the page are not included.",
  "page": "https://casrai.org/guides/iccvam",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-24T13:50:00Z",
  "temporalCoverage": null,
  "spatialCoverage": "United States and OECD member countries",
  "columns": [
    {
      "name": "Method",
      "unit": "",
      "description": ""
    },
    {
      "name": "Toxicity area",
      "unit": "",
      "description": ""
    },
    {
      "name": "OECD Test Guideline",
      "unit": "TG number",
      "description": ""
    },
    {
      "name": "Year listed",
      "unit": "year",
      "description": ""
    }
  ],
  "rows": [
    {
      "Method": "Reconstructed human epidermis corrosivity tests",
      "Toxicity area": "Skin corrosivity",
      "OECD Test Guideline": 431,
      "Year listed": 2004
    },
    {
      "Method": "3T3 NRU phototoxicity test",
      "Toxicity area": "Dermal phototoxicity",
      "OECD Test Guideline": 432,
      "Year listed": 2004
    },
    {
      "Method": "Estrogen receptor transactivation assays",
      "Toxicity area": "Endocrine disruptors",
      "OECD Test Guideline": 455,
      "Year listed": 2009
    },
    {
      "Method": "Skin irritation tests using reconstructed epidermis",
      "Toxicity area": "Skin irritation",
      "OECD Test Guideline": 439,
      "Year listed": 2010
    },
    {
      "Method": "In vitro micronucleus test",
      "Toxicity area": "Genetic toxicity",
      "OECD Test Guideline": 487,
      "Year listed": 2010
    },
    {
      "Method": "H295R steroidogenesis assay",
      "Toxicity area": "Endocrine disruptors",
      "OECD Test Guideline": 456,
      "Year listed": 2011
    },
    {
      "Method": "Human cell line activation test",
      "Toxicity area": "Skin sensitization",
      "OECD Test Guideline": "442E",
      "Year listed": 2016
    },
    {
      "Method": "Defined approaches on skin sensitization",
      "Toxicity area": "Skin sensitization",
      "OECD Test Guideline": 497,
      "Year listed": 2021
    },
    {
      "Method": "Defined approaches for eye damage and irritation",
      "Toxicity area": "Eye irritation and corrosivity",
      "OECD Test Guideline": 467,
      "Year listed": 2022
    }
  ],
  "sources": [
    {
      "title": "NIEHS National Toxicology Program: Accepted Alternative Methods",
      "url": "https://ntp.niehs.nih.gov/whatwestudy/niceatm/accept-methods",
      "accessed": "2026-11-21"
    }
  ]
}