  "name": "ICH Q1E extrapolation limits for retest period or shelf life, by storage class and data scenario",
  "description": "Every maximum extrapolation limit that ICH Q1E (Step 4, 6 February 2003) states in Sections 2.4 and 2.5 for proposing a retest period or shelf life beyond long-term data, arranged by storage class and by the behaviour of accelerated, intermediate and long-term data. X is the period covered by long-term data and Y is the proposed period. Compiled from the guideline text and its Appendix A decision tree.",
  "page": "https://casrai.org/guides/ich-q1e",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-14T12:22:08Z",
  "temporalCoverage": "ICH Q1E Step 4 text dated 2003-02-06",
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Storage class",
      "unit": "",
      "description": ""
    },
    {
      "name": "Data scenario",
      "unit": "",
      "description": ""
    },
    {
      "name": "Statistical analysis",
      "unit": "",
      "description": ""
    },
    {
      "name": "Maximum proposed period Y",
      "unit": "",
      "description": ""
    },
    {
      "name": "Q1E section",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Storage class": "Room temperature",
      "Data scenario": "No significant change at accelerated; long-term and accelerated show little or no change and little or no variability",
      "Statistical analysis": "Normally unnecessary (omission needs justification)",
      "Maximum proposed period Y": "Up to 2X, not more than X + 12 months",
      "Q1E section": "2.4.1.1"
    },
    {
      "Storage class": "Room temperature",
      "Data scenario": "No significant change at accelerated; change or variability; data not amenable, or amenable but not analysed",
      "Statistical analysis": "Not performed; relevant supporting data",
      "Maximum proposed period Y": "Up to 1.5X, not more than X + 6 months",
      "Q1E section": "2.4.1.2"
    },
    {
      "Storage class": "Room temperature",
      "Data scenario": "No significant change at accelerated; change or variability; data amenable and analysed",
      "Statistical analysis": "Performed, backing the proposal with supporting data",
      "Maximum proposed period Y": "Up to 2X, not more than X + 12 months",
      "Q1E section": "2.4.1.2"
    },
    {
      "Storage class": "Room temperature",
      "Data scenario": "Significant change at accelerated, none at intermediate; data not amenable, or amenable but not analysed",
      "Statistical analysis": "Not performed; relevant supporting data",
      "Maximum proposed period Y": "Up to X + 3 months",
      "Q1E section": "2.4.2.1"
    },
    {
      "Storage class": "Room temperature",
      "Data scenario": "Significant change at accelerated, none at intermediate; data amenable and analysed",
      "Statistical analysis": "Performed, backing the proposal with supporting data",
      "Maximum proposed period Y": "Up to 1.5X, not more than X + 6 months",
      "Q1E section": "2.4.2.1"
    },
    {
      "Storage class": "Room temperature",
      "Data scenario": "Significant change at the intermediate condition",
      "Statistical analysis": "Statistics can verify if long-term data vary",
      "Maximum proposed period Y": "Not more than X; a shorter period can be called for",
      "Q1E section": "2.4.2.2"
    },
    {
      "Storage class": "Refrigerator",
      "Data scenario": "No significant change at accelerated; little change and little variability",
      "Statistical analysis": "Normally without statistical analysis",
      "Maximum proposed period Y": "Up to 1.5X, not more than X + 6 months",
      "Q1E section": "2.5.1.1"
    },
    {
      "Storage class": "Refrigerator",
      "Data scenario": "No significant change at accelerated; change or variability; not analysed or not amenable, with supporting data",
      "Statistical analysis": "Not performed",
      "Maximum proposed period Y": "Up to X + 3 months",
      "Q1E section": "2.5.1.1"
    },
    {
      "Storage class": "Refrigerator",
      "Data scenario": "No significant change at accelerated; change or variability; amenable and analysed",
      "Statistical analysis": "Performed, backing the proposal with supporting data",
      "Maximum proposed period Y": "Up to 1.5X, not more than X + 6 months",
      "Q1E section": "2.5.1.1"
    },
    {
      "Storage class": "Refrigerator",
      "Data scenario": "Significant change at accelerated between 3 and 6 months",
      "Statistical analysis": "Verification by statistics can be appropriate if long-term data vary",
      "Maximum proposed period Y": "Based on long-term data; no extrapolation; shorter period can be called for",
      "Q1E section": "2.5.1.2"
    },
    {
      "Storage class": "Refrigerator",
      "Data scenario": "Significant change at accelerated within the first 3 months",
      "Statistical analysis": "Verification by statistics can be appropriate if long-term data vary",
      "Maximum proposed period Y": "Based on long-term data; no extrapolation; excursion discussion required",
      "Q1E section": "2.5.1.2"
    },
    {
      "Storage class": "Freezer",
      "Data scenario": "Intended for freezer storage",
      "Statistical analysis": "Not stated",
      "Maximum proposed period Y": "Based on long-term data; one batch tested at an elevated temperature for excursions",
      "Q1E section": "2.5.2"
    },
    {
      "Storage class": "Below -20 C",
      "Data scenario": "Intended for storage below -20 C",
      "Statistical analysis": "Not stated",
      "Maximum proposed period Y": "Based on long-term data; assessed case by case",
      "Q1E section": "2.5.3"
    }
  ],
  "sources": [
    {
      "title": "ICH Q1E Evaluation for Stability Data, Step 4 (6 February 2003)",
      "url": "https://database.ich.org/sites/default/files/Q1E%20Guideline.pdf",
      "accessed": "2026-11-14"
    }
  ]
}