  "name": "IEC 61215-2:2021 module quality tests (MQT) with clause numbers and 2021 edition changes",
  "description": "Each module quality test listed in the contents of IEC 61215-2 edition 2.0 (2021), with its clause number and the change, if any, that the standard's foreword lists against the 2016 edition. Compiled from the standard's published front matter and the IEC webstore page for Part 1.",
  "page": "https://casrai.org/guides/iec-61215",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-20T22:18:52Z",
  "temporalCoverage": "2021",
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Test",
      "unit": "",
      "description": ""
    },
    {
      "name": "Test name",
      "unit": "",
      "description": ""
    },
    {
      "name": "Clause in IEC 61215-2:2021",
      "unit": "",
      "description": ""
    },
    {
      "name": "Change against 2016 edition per foreword",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Test": "MQT 01",
      "Test name": "Visual inspection",
      "Clause in IEC 61215-2:2021": "4.1",
      "Change against 2016 edition per foreword": "No change listed in foreword"
    },
    {
      "Test": "MQT 02",
      "Test name": "Maximum power determination",
      "Clause in IEC 61215-2:2021": "4.2",
      "Change against 2016 edition per foreword": "No change listed in foreword"
    },
    {
      "Test": "MQT 03",
      "Test name": "Insulation test",
      "Clause in IEC 61215-2:2021": "4.3",
      "Change against 2016 edition per foreword": "No change listed in foreword"
    },
    {
      "Test": "MQT 04",
      "Test name": "Measurement of temperature coefficients",
      "Clause in IEC 61215-2:2021": "4.4",
      "Change against 2016 edition per foreword": "No change listed in foreword"
    },
    {
      "Test": "MQT 06.1",
      "Test name": "Performance at STC",
      "Clause in IEC 61215-2:2021": "4.6",
      "Change against 2016 edition per foreword": "No change listed in foreword"
    },
    {
      "Test": "MQT 07",
      "Test name": "Performance at low irradiance",
      "Clause in IEC 61215-2:2021": "4.7",
      "Change against 2016 edition per foreword": "No change listed in foreword"
    },
    {
      "Test": "MQT 08",
      "Test name": "Outdoor exposure test",
      "Clause in IEC 61215-2:2021": "4.8",
      "Change against 2016 edition per foreword": "No change listed in foreword"
    },
    {
      "Test": "MQT 09",
      "Test name": "Hot-spot endurance test",
      "Clause in IEC 61215-2:2021": "4.9",
      "Change against 2016 edition per foreword": "Procedure corrected for MQT 09.2"
    },
    {
      "Test": "MQT 10",
      "Test name": "UV preconditioning test",
      "Clause in IEC 61215-2:2021": "4.10",
      "Change against 2016 edition per foreword": "No change listed in foreword"
    },
    {
      "Test": "MQT 11",
      "Test name": "Thermal cycling test",
      "Clause in IEC 61215-2:2021": "4.11",
      "Change against 2016 edition per foreword": "Weights added to junction box (Part 1)"
    },
    {
      "Test": "MQT 12",
      "Test name": "Humidity-freeze test",
      "Clause in IEC 61215-2:2021": "4.12",
      "Change against 2016 edition per foreword": "No change listed in foreword"
    },
    {
      "Test": "MQT 13",
      "Test name": "Damp heat test",
      "Clause in IEC 61215-2:2021": "4.13",
      "Change against 2016 edition per foreword": "No change listed in foreword"
    },
    {
      "Test": "MQT 14",
      "Test name": "Robustness of terminations",
      "Clause in IEC 61215-2:2021": "4.14",
      "Change against 2016 edition per foreword": "No change listed in foreword"
    },
    {
      "Test": "MQT 15",
      "Test name": "Wet leakage current test",
      "Clause in IEC 61215-2:2021": "4.15",
      "Change against 2016 edition per foreword": "No change listed in foreword"
    },
    {
      "Test": "MQT 16",
      "Test name": "Static mechanical load test",
      "Clause in IEC 61215-2:2021": "4.16",
      "Change against 2016 edition per foreword": "No change listed in foreword"
    },
    {
      "Test": "MQT 17",
      "Test name": "Hail test",
      "Clause in IEC 61215-2:2021": "4.17",
      "Change against 2016 edition per foreword": "No change listed in foreword"
    },
    {
      "Test": "MQT 18",
      "Test name": "Bypass diode testing",
      "Clause in IEC 61215-2:2021": "4.18",
      "Change against 2016 edition per foreword": "Three diodes selected for thermal test"
    },
    {
      "Test": "MQT 19",
      "Test name": "Stabilization",
      "Clause in IEC 61215-2:2021": "4.19",
      "Change against 2016 edition per foreword": "No change listed in foreword"
    },
    {
      "Test": "MQT 20",
      "Test name": "Cyclic (dynamic) mechanical load test",
      "Clause in IEC 61215-2:2021": "4.20",
      "Change against 2016 edition per foreword": "Added in 2021 edition"
    },
    {
      "Test": "MQT 21",
      "Test name": "Potential induced degradation test",
      "Clause in IEC 61215-2:2021": "4.21",
      "Change against 2016 edition per foreword": "Added in 2021 edition"
    },
    {
      "Test": "MQT 22",
      "Test name": "Bending test",
      "Clause in IEC 61215-2:2021": "4.22",
      "Change against 2016 edition per foreword": "Added in 2021 edition"
    }
  ],
  "sources": [
    {
      "title": "IEC 61215-2:2021 contents, foreword and scope preview",
      "url": "https://assets.vde-verlag.de/iec-normen/preview-pdf/info_iec61215-2%7Bed2.0%7Db.pdf",
      "accessed": "2026-11-20"
    },
    {
      "title": "IEC 61215-1:2021 IEC Webstore",
      "url": "https://webstore.iec.ch/en/publication/61345",
      "accessed": "2026-11-20"
    }
  ]
}