  "name": "Imaging Flow Cytometry vs Conventional Cytometry Specifications",
  "description": "Original compilation comparing optical parameters, magnification, numerical aperture, pixel dimensions, channel capacities, and acquisition throughput across Amnis ImageStreamX Mk II configurations, Amnis FlowSight, and conventional spectral flow cytometry systems.",
  "page": "https://casrai.org/guides/imagestream",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-14T05:35:31Z",
  "temporalCoverage": "2024/2026",
  "spatialCoverage": "Global",
  "columns": [
    {
      "name": "Platform and Optical Mode",
      "unit": "",
      "description": "Instrument name and objective lens configuration"
    },
    {
      "name": "Magnification Power",
      "unit": "x",
      "description": "Optical objective magnification factor"
    },
    {
      "name": "Numerical Aperture",
      "unit": "NA",
      "description": "Light-gathering angle of the collection objective"
    },
    {
      "name": "Pixel Resolution",
      "unit": "μm²",
      "description": "Effective detector pixel area projected in sample space"
    },
    {
      "name": "Maximum Detection Channels",
      "unit": "channels",
      "description": "Simultaneous optical channels recorded"
    },
    {
      "name": "Maximum Acquisition Rate",
      "unit": "cells/sec",
      "description": "Maximum recommended event throughput"
    },
    {
      "name": "Primary Detector Technology",
      "unit": "",
      "description": "Optical detection sensor architecture"
    },
    {
      "name": "Primary Image Output",
      "unit": "",
      "description": "Output spatial capability and file generation"
    }
  ],
  "rows": [
    {
      "Platform and Optical Mode": "ImageStreamX Mk II (60x Objective)",
      "Magnification Power": 60,
      "Numerical Aperture": 0.9,
      "Pixel Resolution": 0.1,
      "Maximum Detection Channels": 12,
      "Maximum Acquisition Rate": 400,
      "Primary Detector Technology": "TDI-CCD Array",
      "Primary Image Output": "Subcellular organelles, punctate foci, and bacteria (.rif/.cif)"
    },
    {
      "Platform and Optical Mode": "ImageStreamX Mk II (40x Objective)",
      "Magnification Power": 40,
      "Numerical Aperture": 0.75,
      "Pixel Resolution": 0.25,
      "Maximum Detection Channels": 12,
      "Maximum Acquisition Rate": 1000,
      "Primary Detector Technology": "TDI-CCD Array",
      "Primary Image Output": "Nuclear translocation and single-cell morphology (.rif/.cif)"
    },
    {
      "Platform and Optical Mode": "ImageStreamX Mk II (20x Objective)",
      "Magnification Power": 20,
      "Numerical Aperture": 0.4,
      "Pixel Resolution": 1,
      "Maximum Detection Channels": 12,
      "Maximum Acquisition Rate": 2000,
      "Primary Detector Technology": "TDI-CCD Array",
      "Primary Image Output": "Large mammalian cells, parasites, and doublets (.rif/.cif)"
    },
    {
      "Platform and Optical Mode": "Amnis FlowSight (20x Fixed)",
      "Magnification Power": 20,
      "Numerical Aperture": 0.4,
      "Pixel Resolution": 1,
      "Maximum Detection Channels": 12,
      "Maximum Acquisition Rate": 4000,
      "Primary Detector Technology": "TDI-CCD Array",
      "Primary Image Output": "Benchtop immunophenotyping and basic morphology (.rif/.cif)"
    },
    {
      "Platform and Optical Mode": "Conventional Spectral Cytometry",
      "Magnification Power": 0,
      "Numerical Aperture": 0,
      "Pixel Resolution": 0,
      "Maximum Detection Channels": 64,
      "Maximum Acquisition Rate": 30000,
      "Primary Detector Technology": "Avalanche Photodiode (APD)",
      "Primary Image Output": "Integrated pulse intensities without spatial imagery (.fcs)"
    }
  ],
  "sources": [
    {
      "title": "Cytek Amnis ImageStreamX Mk II Technical Specifications",
      "url": "https://cytekbio.com/pages/amnis-imagestreamx-mk-ii",
      "accessed": "2026-11-14"
    },
    {
      "title": "Cytek Amnis FlowSight System Specifications",
      "url": "https://cytekbio.com/",
      "accessed": "2026-11-14"
    },
    {
      "title": "Imaging flow cytometry: a primer (Nature Reviews Methods Primers)",
      "url": "https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10468826/",
      "accessed": "2026-11-14"
    }
  ]
}