  "name": "Immunopeptidomics Workflow Parameters Across Primary Isolation and Detection Modalities",
  "description": "Comparative benchmark of laboratory input requirements, target complexes, peptide length distributions, antibody clones, and typical identification yields compiled from HUPO-HIPP MIAIPE guidelines, Nature Protocols, and manufacturer technical notes.",
  "page": "https://casrai.org/guides/immunopeptidomics",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-25T08:15:00Z",
  "temporalCoverage": "2018-2026",
  "spatialCoverage": "Global",
  "columns": [
    {
      "name": "Isolation Modality",
      "unit": "",
      "description": "Primary biochemical capture method or targeted complex"
    },
    {
      "name": "Cell Input",
      "unit": "cells",
      "description": "Typical cell quantity required for robust MS identification"
    },
    {
      "name": "Target Complex",
      "unit": "",
      "description": "Targeted histocompatibility complex class and allele specificity"
    },
    {
      "name": "Peptide Length",
      "unit": "amino acids",
      "description": "Predominant length range of eluted peptide cargo"
    },
    {
      "name": "Primary Antibody Clone",
      "unit": "",
      "description": "Standard monoclonal antibody clone used for affinity capture"
    },
    {
      "name": "Typical Identification Yield",
      "unit": "unique peptides",
      "description": "Typical unique peptide yield from standard nano-LC-MS/MS run"
    },
    {
      "name": "Operational Focus",
      "unit": "",
      "description": "Primary experimental strength and analytical constraint"
    }
  ],
  "rows": [
    {
      "Isolation Modality": "Pan-HLA Class I Immunoaffinity",
      "Cell Input": 100000000,
      "Target Complex": "HLA-A, HLA-B, HLA-C",
      "Peptide Length": "8 to 12",
      "Primary Antibody Clone": "W6/32",
      "Typical Identification Yield": 5000,
      "Operational Focus": "Broadest Class I discovery; requires post-hoc bioinformatic allele deconvolution"
    },
    {
      "Isolation Modality": "Allele-Specific Class I Immunoaffinity",
      "Cell Input": 100000000,
      "Target Complex": "HLA-A*02:01",
      "Peptide Length": "8 to 11",
      "Primary Antibody Clone": "BB7.2",
      "Typical Identification Yield": 2500,
      "Operational Focus": "Direct allele attribution without deconvolution; restricted to A2-positive alleles"
    },
    {
      "Isolation Modality": "Pan-HLA-DR Class II Immunoaffinity",
      "Cell Input": 200000000,
      "Target Complex": "HLA-DR heterodimers",
      "Peptide Length": "12 to 25",
      "Primary Antibody Clone": "L243",
      "Typical Identification Yield": 3500,
      "Operational Focus": "Captures CD4+ epitopes; nested truncation sets require core alignment algorithms"
    },
    {
      "Isolation Modality": "Pan-HLA-DQ Class II Immunoaffinity",
      "Cell Input": 200000000,
      "Target Complex": "HLA-DQ heterodimers",
      "Peptide Length": "12 to 25",
      "Primary Antibody Clone": "SPV-L3",
      "Typical Identification Yield": 1800,
      "Operational Focus": "Celiac and autoimmune epitope mapping; lower expression than HLA-DR in most tissues"
    },
    {
      "Isolation Modality": "Mild Acid Elution (Viable Surface Elution)",
      "Cell Input": 50000000,
      "Target Complex": "Cell surface Class I complexes",
      "Peptide Length": "8 to 12",
      "Primary Antibody Clone": "None (Citrate-Phosphate)",
      "Typical Identification Yield": 800,
      "Operational Focus": "Rapid non-destructive sampling; higher cytosolic background from membrane fragility"
    }
  ],
  "sources": [
    {
      "title": "Minimal Information About an Immuno-Peptidomics Experiment (MIAIPE)",
      "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC6033177/",
      "accessed": "2026-11-19"
    },
    {
      "title": "Mass spectrometry-based identification of MHC-bound peptides for immunopeptidomics",
      "url": "https://www.nature.com/articles/s41596-019-0133-y",
      "accessed": "2026-11-19"
    },
    {