  "name": "OSHA-described sampler and media by airborne contaminant",
  "description": "Compares the sampler, collection medium, flow rate and placement notes that OSHA's Technical Manual gives for each class of airborne contaminant, compiled from the manual's personal sampling chapter.",
  "page": "https://casrai.org/guides/industrial-hygiene-sampling",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-22T14:10:00Z",
  "temporalCoverage": null,
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Contaminant",
      "unit": "",
      "description": ""
    },
    {
      "name": "Sampler or cassette",
      "unit": "",
      "description": ""
    },
    {
      "name": "Collection medium",
      "unit": "",
      "description": ""
    },
    {
      "name": "Flow rate or limit",
      "unit": "as stated",
      "description": ""
    },
    {
      "name": "Placement or handling note",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Contaminant": "Total dust",
      "Sampler or cassette": "Sampling cassette",
      "Collection medium": "Pre-weighed PVC filter",
      "Flow rate or limit": "Maximum 2 L/min, up to 480 min",
      "Placement or handling note": "Check for overloading: loose material, darkening, reduced flow"
    },
    {
      "Contaminant": "Respirable dust",
      "Sampler or cassette": "Size-selective cyclone (Dorr-Oliver)",
      "Collection medium": "Pre-weighed PVC filter",
      "Flow rate or limit": "1.7 L/min; 50% cut point 4.0 µm",
      "Placement or handling note": "Keep cyclone vertical; use SKC PPI where it could invert"
    },
    {
      "Contaminant": "Welding fume",
      "Sampler or cassette": "Cassette inside helmet",
      "Collection medium": "37-mm mixed cellulose ester filter",
      "Flow rate or limit": "Not specified in this section",
      "Placement or handling note": "25-mm filter if 37-mm does not fit; place at collar or shoulder inside helmet"
    },
    {
      "Contaminant": "Asbestos",
      "Sampler or cassette": "Conductive cassette with 50-mm extension cowl",
      "Collection medium": "0.8-µm, 25-mm mixed cellulose ester filter",
      "Flow rate or limit": "Not specified in this section",
      "Placement or handling note": "Open face pointing downward in the breathing zone; seal bottom joint"
    },
    {
      "Contaminant": "Respirable crystalline silica",
      "Sampler or cassette": "Respirable size-selector such as a Dorr-Oliver cyclone",
      "Collection medium": "Respirable sample; analysis requested as crystalline silica",
      "Flow rate or limit": "Not specified in this section",
      "Placement or handling note": "Without a size-selector the sample is treated as total dust"
    },
    {
      "Contaminant": "Surface contamination",
      "Sampler or cassette": "Wipe with 10 cm x 10 cm template",
      "Collection medium": "Wipe moistened with distilled water or suitable solvent",
      "Flow rate or limit": "Not applicable",
      "Placement or handling note": "Semi-quantitative; no OSHA surface limits specified"
    }
  ],
  "sources": [
    {
      "title": "OSHA Technical Manual, Section II, Chapter 1",
      "url": "https://www.osha.gov/otm/section-2-health-hazards/chapter-1",
      "accessed": "2026-11-21"
    },
    {
      "title": "OSHA Technical Manual, Section II, Chapter 2",
      "url": "https://www.osha.gov/otm/section-2-health-hazards/chapter-2",
      "accessed": "2026-11-21"
    }
  ]
}