  "name": "PBMC Density Gradient Media and Platform Specifications",
  "description": "Comparative technical parameters, physical properties, centrifugal conditions, and performance recovery benchmarks for peripheral blood mononuclear cell (PBMC) isolation media and barrier systems compiled from manufacturer technical specifications and published protocols.",
  "page": "https://casrai.org/guides/isolating-pbmcs",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-16T05:04:33Z",
  "temporalCoverage": "2024/2026",
  "spatialCoverage": "Global",
  "columns": [
    {
      "name": "Isolation Platform or Medium",
      "unit": "",
      "description": "Trade name and manufacturer of the density gradient medium or tube system"
    },
    {
      "name": "Density at 20C",
      "unit": "g/mL",
      "description": "Specific gravity of the formulated separation solution"
    },
    {
      "name": "Recommended Centrifugal Force",
      "unit": "x g",
      "description": "Optimal relative centrifugal force (RCF) for separation"
    },
    {
      "name": "Centrifugation Duration",
      "unit": "minutes",
      "description": "Standard centrifugation run time at recommended RCF"
    },
    {
      "name": "Deceleration Brake Setting",
      "unit": "",
      "description": "Centrifuge brake status required to maintain interface integrity"
    },
    {
      "name": "Typical PBMC Recovery",
      "unit": "%",
      "description": "Percentage of mononuclear cells recovered relative to starting blood sample"
    },
    {
      "name": "Mononuclear Cell Purity",
      "unit": "%",
      "description": "Percentage of isolated cells that are mononuclear (lymphocytes and monocytes)"
    },
    {
      "name": "Endotoxin Level",
      "unit": "EU/mL",
      "description": "Maximum endotoxin concentration certified by the manufacturer"
    }
  ],
  "rows": [
    {
      "Isolation Platform or Medium": "Cytiva Ficoll-Paque PLUS",
      "Density at 20C": 1.077,
      "Recommended Centrifugal Force": 400,
      "Centrifugation Duration": 35,
      "Deceleration Brake Setting": "Off (Coast)",
      "Typical PBMC Recovery": 60,
      "Mononuclear Cell Purity": 95,
      "Endotoxin Level": 0.12
    },
    {
      "Isolation Platform or Medium": "Cytiva Ficoll-Paque PREMIUM",
      "Density at 20C": 1.077,
      "Recommended Centrifugal Force": 400,
      "Centrifugation Duration": 35,
      "Deceleration Brake Setting": "Off (Coast)",
      "Typical PBMC Recovery": 60,
      "Mononuclear Cell Purity": 95,
      "Endotoxin Level": 0.05
    },
    {
      "Isolation Platform or Medium": "Sigma-Aldrich Histopaque-1077",
      "Density at 20C": 1.077,
      "Recommended Centrifugal Force": 400,
      "Centrifugation Duration": 30,
      "Deceleration Brake Setting": "Off (Coast)",
      "Typical PBMC Recovery": 65,
      "Mononuclear Cell Purity": 95,
      "Endotoxin Level": 3
    },
    {
      "Isolation Platform or Medium": "STEMCELL Technologies SepMate-50",
      "Density at 20C": 1.077,
      "Recommended Centrifugal Force": 1200,
      "Centrifugation Duration": 10,
      "Deceleration Brake Setting": "On (Active)",
      "Typical PBMC Recovery": 70,
      "Mononuclear Cell Purity": 95,
      "Endotoxin Level": 0.12
    },
    {
      "Isolation Platform or Medium": "BD Vacutainer CPT (Sodium Citrate)",
      "Density at 20C": 1.077,
      "Recommended Centrifugal Force": 1650,
      "Centrifugation Duration": 25,
      "Deceleration Brake Setting": "On (Gentle)",
      "Typical PBMC Recovery": 65,
      "Mononuclear Cell Purity": 90,
      "Endotoxin Level": 0.5
    },
    {
      "Isolation Platform or Medium": "BD Vacutainer CPT (Sodium Heparin)",
      "Density at 20C": 1.077,
      "Recommended Centrifugal Force": 1650,
      "Centrifugation Duration": 20,
      "Deceleration Brake Setting": "On (Gentle)",
      "Typical PBMC Recovery": 65,
      "Mononuclear Cell Purity": 90,
      "Endotoxin Level": 0.5
    }
  ],
  "sources": [
    {
      "title": "Cytiva Ficoll-Paque PLUS Instructions for Use (71-7167-00 AD)",
      "url": "https://www.cytivalifesciences.com/en/us/shop/cell-therapy/isolation/ficoll-paque-plus-density-gradient-media-p-00175",
      "accessed": "2026-11-16"
    },
    {
      "title": "Sigma-Aldrich Histopaque-1077 Product Information Specification",
      "url": "https://www.sigmaaldrich.com/US/en/product/sigma/10771",
      "accessed": "2026-11-16"
    },
    {
      "title": "STEMCELL Technologies SepMate-50 Product Information Sheet (Document #DX20324)",
      "url": "https://www.stemcell.com/sepmate-50.html",
      "accessed": "2026-11-16"
    },
    {
      "title": "BD Vacutainer CPT Cell Preparation Tube Instructions for Use",
      "url": "https://www.bdbiosciences.com/en-us/products/blood-collection/cpt-tubes",
      "accessed": "2026-11-16"
    }
  ]
}