{
  "name": "MATLAB Control System Toolbox: task, function, output and extra product needed",
  "description": "Maps common linear-control tasks to the documented Control System Toolbox function or app, what it returns, and any additional MathWorks product the documentation says is required. Compiled from the MathWorks reference pages.",
  "page": "https://casrai.org/guides/matlab-control-system-toolbox",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-15T15:30:57Z",
  "temporalCoverage": null,
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Task",
      "unit": "",
      "description": ""
    },
    {
      "name": "Function or app",
      "unit": "",
      "description": ""
    },
    {
      "name": "Output",
      "unit": "",
      "description": ""
    },
    {
      "name": "Additional product documented as required",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Task": "Create a transfer function",
      "Function or app": "tf(numerator,denominator)",
      "Output": "tf object (genss if tunable, uss if uncertain)",
      "Additional product documented as required": "Robust Control Toolbox for uncertain (uss) models"
    },
    {
      "Task": "Create an identified transfer function",
      "Function or app": "idtf",
      "Output": "Identified model",
      "Additional product documented as required": "System Identification Toolbox"
    },
    {
      "Task": "Plot or compute a step response",
      "Function or app": "step(sys)",
      "Output": "Plot, or [y,tOut] data",
      "Additional product documented as required": "None stated"
    },
    {
      "Task": "Measure rise time, settling time, overshoot",
      "Function or app": "stepinfo(sys)",
      "Output": "Structure of response characteristics",
      "Additional product documented as required": "None stated"
    },
    {
      "Task": "Plot frequency response",
      "Function or app": "bode(sys)",
      "Output": "Magnitude (dB) and phase (deg) vs frequency",
      "Additional product documented as required": "None stated"
    },
    {
      "Task": "Tune a SISO controller interactively",
      "Function or app": "controlSystemDesigner",
      "Output": "Tuned compensator, exportable blocks or Simulink model",
      "Additional product documented as required": "Simulink Control Design for Simulink models"
    },
    {
      "Task": "Optimisation-based controller tuning",
      "Function or app": "controlSystemDesigner",
      "Output": "Tuned controller parameters",
      "Additional product documented as required": "Simulink Design Optimization"
    }
  ],
  "sources": [
    {
      "title": "MathWorks tf reference",
      "url": "https://www.mathworks.com/help/control/ref/tf.html",
      "accessed": "2026-11-15"
    },
    {
      "title": "MathWorks step reference",
      "url": "https://www.mathworks.com/help/control/ref/dynamicsystem.step.html",
      "accessed": "2026-11-15"
    },
    {
      "title": "MathWorks stepinfo reference",
      "url": "https://www.mathworks.com/help/control/ref/dynamicsystem.stepinfo.html",
      "accessed": "2026-11-15"
    },
    {
      "title": "MathWorks bode reference",
      "url": "https://www.mathworks.com/help/control/ref/dynamicsystem.bode.html",
      "accessed": "2026-11-15"
    },
    {
      "title": "MathWorks controlSystemDesigner reference",
      "url": "https://www.mathworks.com/help/control/ref/controlsystemdesigner-app.html",
      "accessed": "2026-11-15"
    }
  ]
}