  "name": "Four microscope slide preparation routes compared: fixation, support and size figures",
  "description": "Compares wet mount, KOH mount, heat or methanol fixed smear and paraffin tissue section by how the specimen is stabilised, how it sits on the slide and the size or thickness figures stated in a CDC training exercise and in university microbiology and histology teaching material.",
  "page": "https://casrai.org/guides/microscope-slide-preparation",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-16T16:05:00Z",
  "temporalCoverage": null,
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Preparation route",
      "unit": "",
      "description": ""
    },
    {
      "name": "Fixation or stabilisation",
      "unit": "",
      "description": ""
    },
    {
      "name": "How the specimen sits on the slide",
      "unit": "",
      "description": ""
    },
    {
      "name": "Size or thickness figure stated",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Preparation route": "Wet mount",
      "Fixation or stabilisation": "None; observed at once",
      "How the specimen sits on the slide": "Drop of liquid under a coverslip",
      "Size or thickness figure stated": "Example organism Trichomonads about 15 µm (observed at 40X)"
    },
    {
      "Preparation route": "KOH mount",
      "Fixation or stabilisation": "KOH added to the drop; observed at once",
      "How the specimen sits on the slide": "Drop of specimen plus KOH under a coverslip",
      "Size or thickness figure stated": "Yeast 2-6 µm; pseudohyphae 20-100 µm (observed at 40X)"
    },
    {
      "Preparation route": "Smear",
      "Fixation or stabilisation": "Heat fixation, or chemical fixative such as methanol",
      "How the specimen sits on the slide": "Thin layer spread on the slide",
      "Size or thickness figure stated": "No figure stated"
    },
    {
      "Preparation route": "Paraffin tissue section",
      "Fixation or stabilisation": "Fixation, then alcohol dehydration and paraffin infiltration",
      "How the specimen sits on the slide": "Microtome section mounted on glass, sealed with mounting medium and a thin cover glass",
      "Size or thickness figure stated": "Sections 3-10 µm (Columbia); 1-10 µm light level (Iowa)"
    }
  ],
  "sources": [
    {
      "title": "CDC REACH Routine Microscopy Procedures Student Laboratory Exercises",
      "url": "https://reach.cdc.gov/sites/default/files/job-aids-resources/Routine-Microscopy-Student-Laboratory-Exercises_508.pdf",
      "accessed": "2026-11-15"
    },
    {
      "title": "LibreTexts Introduction to Microbiology 2.7 Sample Preparation for Microscopic Staining",
      "url": "https://bio.libretexts.org/Bookshelves/Microbiology/Introduction_to_Microbiology_(Liu_et_al.)/02%3A_Microscopes/2.07%3A_Sample_Preparation_for_Microscopic_Staining",
      "accessed": "2026-11-15"
    },
    {
      "title": "Columbia University histology laboratory, Histological Techniques",
      "url": "https://histologylab.ctl.columbia.edu/histological_techniques/",
      "accessed": "2026-11-15"
    },
    {
      "title": "University of Iowa Central Microscopy Research Facility",
      "url": "https://cmrf.research.uiowa.edu/node/211",
      "accessed": "2026-11-15"
    }
  ]
}