{
  "name": "Configuration of five published university MBE systems",
  "description": "Compares base pressure, number of sources, source types, in-situ monitoring and sample-transfer features of molecular-beam epitaxy systems, compiled from each facility's own public description page read on 2026-11-13.",
  "page": "https://casrai.org/guides/molecular-beam-epitaxy",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-13T06:15:19Z",
  "temporalCoverage": "2026",
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Facility",
      "unit": "",
      "description": ""
    },
    {
      "name": "Base pressure statement",
      "unit": "",
      "description": ""
    },
    {
      "name": "Sources",
      "unit": "",
      "description": ""
    },
    {
      "name": "In-situ monitoring",
      "unit": "",
      "description": ""
    },
    {
      "name": "Sample transfer and other notes",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Facility": "Stanford ARPES group (chalcogenide and oxide systems)",
      "Base pressure statement": "Low 10^-11 Torr range (MBE and ARPES chambers)",
      "Sources": "Up to eight elements: four effusion cells plus a four-pocket e-beam evaporator; cracker cell; ozone source in oxide system",
      "In-situ monitoring": "RHEED",
      "Sample transfer and other notes": "MBE connected in vacuum to ARPES for in-situ study"
    },
    {
      "Facility": "University of Texas at Austin",
      "Base pressure statement": "1.5x10^-10 Torr",
      "Sources": "Six effusion cells (four standard, two high-temperature)",
      "In-situ monitoring": "Differentially pumped RHEED",
      "Sample transfer and other notes": "Cryopump; turbopumped load lock with lamp heating to 150 C; sample heater to 1000 C"
    },
    {
      "Facility": "Emory University",
      "Base pressure statement": "Below 3x10^-10 Torr",
      "Sources": "Six effusion cells",
      "In-situ monitoring": "RHEED-based deposition feedback",
      "Sample transfer and other notes": "Sputtering source in load lock; 1500 C sample heater"
    },
    {
      "Facility": "Ohio State University (Brillson group)",
      "Base pressure statement": "Not stated",
      "Sources": "Nine shuttered effusion cells plus a load-locked three-pocket e-beam evaporator",
      "In-situ monitoring": "1-30 keV RHEED optics",
      "Sample transfer and other notes": "Veeco GEN 930 oxide MBE system; load-locked entry/exit chamber"
    },
    {
      "Facility": "University of Groningen (Zernike Institute)",
      "Base pressure statement": "Not stated (UHV)",
      "Sources": "Several sources: Knudsen cells or e-beam evaporators; oxidising gas supply for oxides",
      "In-situ monitoring": "RHEED intensity oscillations",
      "Sample transfer and other notes": "Three UHV chambers: growth, preparation, analysis (LEED, XPS)"
    }
  ],
  "sources": [
    {
      "title": "Stanford ARPES group, Molecular-beam epitaxy",
      "url": "https://arpes.stanford.edu/research/tool-development/molecular-beam-epitaxy",
      "accessed": "2026-11-13"
    },
    {
      "title": "University of Texas at Austin, MBE laboratory",
      "url": "https://web2.ph.utexas.edu/~aadg/lab/mbe.html",
      "accessed": "2026-11-13"
    },
    {
      "title": "Emory University, Urazhdin group MBE",
      "url": "https://faculty.college.emory.edu/sites/urazhdin/mbe.html",
      "accessed": "2026-11-13"
    },
    {
      "title": "Ohio State University, Brillson group facility",
      "url": "https://u.osu.edu/brillsongroup/?p=764",
      "accessed": "2026-11-13"
    },
    {
      "title": "University of Groningen, Zernike Institute, molecular beam epitaxy",
      "url": "https://www.rug.nl/research/zernike/Nanostructres-of-functional-oxides/molecular-beam-epitaxy",
      "accessed": "2026-11-13"
    }
  ]
}