{
  "name": "Four meanings of 'multiplex' in antibody-based testing",
  "description": "Compares the four settings in which 'multiplex' is used for antibody-based testing: planar array immunoassay, suspension bead immunoassay, multiplex bead autoantibody panel and multiplex immunofluorescence on tissue. Compiled from two peer-reviewed reviews on PubMed Central and one openFDA 510(k) record; each cell restates a point made in the listed source.",
  "page": "https://casrai.org/guides/multiplex-immunoassay",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-20T17:32:54Z",
  "temporalCoverage": "2015/2021",
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Format",
      "unit": "",
      "description": ""
    },
    {
      "name": "What is measured",
      "unit": "",
      "description": ""
    },
    {
      "name": "How targets are told apart",
      "unit": "",
      "description": ""
    },
    {
      "name": "Main reliability concern in the source",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Format": "Planar array immunoassay",
      "What is measured": "Several protein analytes in one sample",
      "How targets are told apart": "Capture ligands at discrete spots on a slide or microtitre plate",
      "Main reliability concern in the source": "Cross-reactivity rises quadratically with number of targets; antibodies validated for singleplex may fail in multiplex"
    },
    {
      "Format": "Suspension bead immunoassay",
      "What is measured": "Several protein analytes in one sample",
      "How targets are told apart": "Fluorescently coded microbeads in liquid phase, flow-cytometry-type readout",
      "Main reliability concern in the source": "Theoretical 100-plex but commercial panels seldom exceed 20 analytes; most assays research use only"
    },
    {
      "Format": "Multiplex bead autoantibody panel",
      "What is measured": "Many autoantibody specificities in one run",
      "How targets are told apart": "Beads of different size or fluorescence, each coated with a different antigen, gated by population",
      "Main reliability concern in the source": "Panels typically detect 8-10 specificities versus about 100-150 autoantigens on HEp-2 cells; not a replacement for IF ANA"
    },
    {
      "Format": "Multiplex immunofluorescence on tissue",
      "What is measured": "Several protein markers on one tissue section",
      "How targets are told apart": "Different markers/fluorophores on a single slide (tyramide signal amplification)",
      "Main reliability concern in the source": "Pre-analytic variation, marker variability, inter-observer variability, umbrella effect and channel crosstalk"
    }
  ],
  "sources": [
    {
      "title": "ELISA in the multiplex era: potentials and pitfalls",
      "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC6680274/",
      "accessed": "2026-11-20"
    },
    {
      "title": "The uses and misuses of multiplex autoantibody assays in systemic autoimmune rheumatic diseases",
      "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC4404943/",
      "accessed": "2026-11-20"
    },
    {
      "title": "Best Practices for Technical Reproducibility Assessment of Multiplex Immunofluorescence",
      "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC8438151/",
      "accessed": "2026-11-20"
    }
  ]
}