  "name": "Nanofiltration qualification tests: flat sheet versus elements",
  "description": "Original compilation of three DuPont qualification documents. Each uses a 2,000 ppm magnesium sulfate feed. Flat-sheet maximum passage and element stabilized rejection are different metrics; values are thresholds, not comparable field performance. The flat-sheet test specifies 7.9 L/min retentate flow and a 20-minute test rather than recovery. The element documents specify 15% recovery. Test pressures are not maximum operating pressures.",
  "page": "https://casrai.org/guides/nanofiltration",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-14T13:00:12Z",
  "temporalCoverage": null,
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Membrane and document revision",
      "unit": "",
      "description": ""
    },
    {
      "name": "Applied test pressure",
      "unit": "bar",
      "description": ""
    },
    {
      "name": "Test temperature",
      "unit": "°C",
      "description": ""
    },
    {
      "name": "Test recovery",
      "unit": "%",
      "description": "Not reported means the flat-sheet source specifies retentate flow instead."
    },
    {
      "name": "Magnesium sulfate threshold",
      "unit": "%",
      "description": ""
    },
    {
      "name": "Metric and qualifier",
      "unit": "",
      "description": "Do not interpret passage and rejection thresholds as the same metric."
    }
  ],
  "rows": [
    {
      "Membrane and document revision": "FilmTec NF270 NF Flatsheet; 45-D01987 Rev.3",
      "Applied test pressure": 8.96,
      "Test temperature": 25,
      "Test recovery": "Not reported",
      "Magnesium sulfate threshold": 0.8,
      "Metric and qualifier": "Maximum passage; mean sample qualification"
    },
    {
      "Membrane and document revision": "FilmTec NF270-4040; 45-D01529 Rev.8",
      "Applied test pressure": 4.8,
      "Test temperature": 25,
      "Test recovery": 15,
      "Magnesium sulfate threshold": 97,
      "Metric and qualifier": "Stabilized rejection greater than threshold"
    },
    {
      "Membrane and document revision": "FilmTec NF90-4040; 45-D01520 Rev.8",
      "Applied test pressure": 4.8,
      "Test temperature": 25,
      "Test recovery": 15,
      "Magnesium sulfate threshold": 98.7,
      "Metric and qualifier": "Stabilized rejection greater than threshold"
    }
  ],
  "sources": [
    {
      "title": "DuPont NF270 NF Flatsheet, 45-D01987-en Rev.3 January 2026",
      "url": "https://www.dupont.com/content/dam/water/amer/us/en/water/public/documents/en/NF-FilmTec-NF270%20Flatsheet-PDS-45-D01987-en.pdf",
      "accessed": "2026-11-14"
    },
    {
      "title": "DuPont NF270 Element, 45-D01529-en Rev.8 January 2025",
      "url": "https://www.dupont.com/content/dam/water/amer/us/en/water/public/documents/en/NF-FilmTec-NF270-PDS-45-D01529-en.pdf",
      "accessed": "2026-11-14"
    },
    {
      "title": "DuPont NF90 Element, 45-D01520-en Rev.8 April 2026",
      "url": "https://www.dupont.com/content/dam/water/amer/us/en/water/public/documents/en/NF-FilmTec-NF90-PDS-45-D01520-en.pdf",
      "accessed": "2026-11-14"
    }
  ]
}