{
  "name": "Quantitative Biophysical and Assay Characteristics of Bioluminescent Reporter Systems",
  "description": "Comparison of biophysical properties, substrate requirements, emission spectra, and performance benchmarks for engineered and native bioluminescent reporters compiled from primary peer-reviewed literature and manufacturer assay manuals.",
  "page": "https://casrai.org/guides/nanoluc",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-14T07:15:29Z",
  "temporalCoverage": null,
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Reporter Enzyme",
      "unit": "",
      "description": "Name and common abbreviation of the bioluminescent reporter protein"
    },
    {
      "name": "Native Organism",
      "unit": "",
      "description": "Source organism of the wild-type luciferase enzyme"
    },
    {
      "name": "Molecular Mass",
      "unit": "kDa",
      "description": "Monomeric molecular weight of the reporter polypeptide"
    },
    {
      "name": "Amino Acid Count",
      "unit": "aa",
      "description": "Total length of the primary amino acid sequence"
    },
    {
      "name": "Substrate",
      "unit": "",
      "description": "Luciferin or coelenterazine analog consumed in light-emitting reaction"
    },
    {
      "name": "Cofactors Required",
      "unit": "",
      "description": "Essential cofactors necessary for enzymatic light emission"
    },
    {
      "name": "Peak Emission",
      "unit": "nm",
      "description": "Peak bioluminescence emission wavelength (lambda max)"
    },
    {
      "name": "Luminescence Half-Life",
      "unit": "min",
      "description": "Typical signal decay half-life in standard glow buffer formulation"
    },
    {
      "name": "Relative Specific Activity",
      "unit": "fold",
      "description": "Relative light output per molecule compared to firefly luciferase"
    },
    {
      "name": "Linear Dynamic Range",
      "unit": "logs",
      "description": "Dynamic range orders of magnitude in cell culture assays"
    }
  ],
  "rows": [
    {
      "Reporter Enzyme": "NanoLuc (Nluc)",
      "Native Organism": "Oplophorus gracilirostris (deep-sea shrimp)",
      "Molecular Mass": 19.1,
      "Amino Acid Count": 171,
      "Substrate": "Furimazine",
      "Cofactors Required": "None (O2 only)",
      "Peak Emission": 460,
      "Luminescence Half-Life": 120,
      "Relative Specific Activity": 150,
      "Linear Dynamic Range": 6
    },
    {
      "Reporter Enzyme": "Firefly Luciferase (Fluc)",
      "Native Organism": "Photinus pyralis (common eastern firefly)",
      "Molecular Mass": 61,
      "Amino Acid Count": 550,
      "Substrate": "D-Luciferin",
      "Cofactors Required": "ATP, Mg2+, O2",
      "Peak Emission": 560,
      "Luminescence Half-Life": 15,
      "Relative Specific Activity": 1,
      "Linear Dynamic Range": 5
    },
    {
      "Reporter Enzyme": "Renilla Luciferase (Rluc)",
      "Native Organism": "Renilla reniformis (sea pansy)",
      "Molecular Mass": 36,
      "Amino Acid Count": 311,
      "Substrate": "Native Coelenterazine",
      "Cofactors Required": "None (O2 only)",
      "Peak Emission": 480,
      "Luminescence Half-Life": 2,
      "Relative Specific Activity": 1,
      "Linear Dynamic Range": 4
    },
    {
      "Reporter Enzyme": "Gaussia Luciferase (Gluc)",
      "Native Organism": "Gaussia princeps (marine copepod)",
      "Molecular Mass": 19.9,
      "Amino Acid Count": 185,
      "Substrate": "Native Coelenterazine",
      "Cofactors Required": "None (O2 only)",
      "Peak Emission": 480,
      "Luminescence Half-Life": 5,
      "Relative Specific Activity": 100,
      "Linear Dynamic Range": 5
    },
    {
      "Reporter Enzyme": "Akaluc",
      "Native Organism": "Engineered Photinus pyralis derivative",
      "Molecular Mass": 61,
      "Amino Acid Count": 550,
      "Substrate": "AkaLumine-HCl",
      "Cofactors Required": "ATP, Mg2+, O2",
      "Peak Emission": 650,
      "Luminescence Half-Life": 40,
      "Relative Specific Activity": 7,
      "Linear Dynamic Range": 5
    }
  ],
  "sources": [
    {
      "title": "Hall et al. (2012) ACS Chem Biol - Engineered Luciferase Reporter",
      "url": "https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3526014/",
      "accessed": "2026-11-14"
    },
    {
      "title": "Promega Nano-Glo Luciferase Assay System TM369",
      "url": "https://www.promega.com/protocols/",
      "accessed": "2026-11-14"
    },
    {
      "title": "Iwano et al. (2018) Science - Akaluc Bioluminescence",
      "url": "https://doi.org/10.1126/science.aaq1067",
      "accessed": "2026-11-14"
    }
  ]
}