  "name": "Nile Red Solvatochromic Properties and Spectral Maxima Across Solvents and Biological Matrices",
  "description": "Comparative experimental compilation of Nile Red (CAS 7385-67-3) photophysical parameters, absorption and emission maxima, solvatochromic bathochromic shifts, and analytical target domains across seven solvent polarities and lipid environments, compiled from peer-reviewed spectroscopy literature and analytical standards.",
  "page": "https://casrai.org/guides/nile-red-dye",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-15T06:52:02Z",
  "temporalCoverage": "1985/2026",
  "spatialCoverage": "Global",
  "columns": [
    {
      "name": "Solvent or Environmental Matrix",
      "unit": "",
      "description": "Chemical solvent or biological reference environment tested"
    },
    {
      "name": "Dielectric Constant",
      "unit": "dimensionless",
      "description": "Relative static permittivity (epsilon) at 20-25 degrees Celsius"
    },
    {
      "name": "Absorption Maximum",
      "unit": "nm",
      "description": "Peak light absorption / excitation wavelength"
    },
    {
      "name": "Fluorescence Emission Maximum",
      "unit": "nm",
      "description": "Peak fluorescence emission wavelength"
    },
    {
      "name": "Bathochromic Shift from Hexane",
      "unit": "nm",
      "description": "Spectral red shift in emission relative to nonpolar n-hexane benchmark"
    },
    {
      "name": "Visual Fluorescence Band",
      "unit": "",
      "description": "Observed visual color band of emitted fluorescence"
    },
    {
      "name": "Primary Biological or Analytical Target",
      "unit": "",
      "description": "Typical analytical application or cellular compartment"
    }
  ],
  "rows": [
    {
      "Solvent or Environmental Matrix": "n-Hexane",
      "Dielectric Constant": 1.88,
      "Absorption Maximum": 485,
      "Fluorescence Emission Maximum": 526,
      "Bathochromic Shift from Hexane": 0,
      "Visual Fluorescence Band": "Yellow-Green",
      "Primary Biological or Analytical Target": "Aliphatic hydrocarbon core benchmark / nonpolar standard"
    },
    {
      "Solvent or Environmental Matrix": "Toluene",
      "Dielectric Constant": 2.38,
      "Absorption Maximum": 514,
      "Fluorescence Emission Maximum": 563,
      "Bathochromic Shift from Hexane": 37,
      "Visual Fluorescence Band": "Yellow",
      "Primary Biological or Analytical Target": "Aromatic microenvironment / polystyrene standard"
    },
    {
      "Solvent or Environmental Matrix": "Chloroform",
      "Dielectric Constant": 4.81,
      "Absorption Maximum": 532,
      "Fluorescence Emission Maximum": 600,
      "Bathochromic Shift from Hexane": 74,
      "Visual Fluorescence Band": "Orange",
      "Primary Biological or Analytical Target": "Neutral lipid droplets / triacylglycerol model"
    },
    {
      "Solvent or Environmental Matrix": "Acetone",
      "Dielectric Constant": 20.7,
      "Absorption Maximum": 535,
      "Fluorescence Emission Maximum": 622,
      "Bathochromic Shift from Hexane": 96,
      "Visual Fluorescence Band": "Red-Orange",
      "Primary Biological or Analytical Target": "Carrier solvent vehicle / microplastic deposition"
    },
    {
      "Solvent or Environmental Matrix": "Ethanol",
      "Dielectric Constant": 24.5,
      "Absorption Maximum": 550,
      "Fluorescence Emission Maximum": 632,
      "Bathochromic Shift from Hexane": 106,
      "Visual Fluorescence Band": "Deep Red",
      "Primary Biological or Analytical Target": "Polar lipid extracts / amphiphilic fractions"
    },
    {
      "Solvent or Environmental Matrix": "Methanol",
      "Dielectric Constant": 32.7,
      "Absorption Maximum": 552,
      "Fluorescence Emission Maximum": 636,
      "Bathochromic Shift from Hexane": 110,
      "Visual Fluorescence Band": "Deep Red",
      "Primary Biological or Analytical Target": "Membrane phospholipids / standard analytical benchmark"
    },
    {
      "Solvent or Environmental Matrix": "Aqueous Saline (PBS)",
      "Dielectric Constant": 80.1,
      "Absorption Maximum": 590,
      "Fluorescence Emission Maximum": 660,
      "Bathochromic Shift from Hexane": 134,
      "Visual Fluorescence Band": "Quenched (",
      "Primary Biological or Analytical Target": "Aqueous background / unpartitioned dye"
    }
  ],
  "sources": [
    {
      "title": "Nile red as a polarity-sensitive fluorescent probe of hydrophobic sites in proteins (Sackett & Wolff, 1987)",
      "url": "https://pubmed.ncbi.nlm.nih.gov/3442318/",
      "accessed": "2026-11-15"
    },
    {
      "title": "Nile red: a selective fluorescent stain for intracellular lipid droplets (Greenspan et al., 1985)",
      "url": "https://pubmed.ncbi.nlm.nih.gov/3976727/",
      "accessed": "2026-11-15"
    },
    {
      "title": "Invitrogen Nile Red Technical Data Sheet (Thermo Fisher Catalog N1142)",
      "url": "https://www.thermofisher.com/order/catalog/product/N1142",
      "accessed": "2026-11-15"
    },
    {
      "title": "PubChem Compound Summary for CID 65182, Nile Red",
      "url": "https://pubchem.ncbi.nlm.nih.gov/compound/65182",
      "accessed": "2026-11-15"
    }
  ]
}