  "name": "Hydraulic jump form, effect and energy loss by upstream Froude number",
  "description": "Compiled from FHWA HEC-14 chapter 6, which reports U.S. Bureau of Reclamation (1987) jump forms by upstream Froude number. Each row gives the Froude range, the jump form, the downstream behaviour the manual describes, and the energy loss where the manual states one.",
  "page": "https://casrai.org/guides/open-channel-flow",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-15T16:04:45Z",
  "temporalCoverage": "2006",
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Upstream Froude number range",
      "unit": "",
      "description": ""
    },
    {
      "name": "Jump form",
      "unit": "",
      "description": ""
    },
    {
      "name": "Behaviour described in HEC-14",
      "unit": "",
      "description": ""
    },
    {
      "name": "Energy loss",
      "unit": "percent",
      "description": ""
    }
  ],
  "rows": [
    {
      "Upstream Froude number range": "1.0",
      "Jump form": "No jump forms",
      "Behaviour described in HEC-14": "Flow is at critical depth",
      "Energy loss": "not applicable"
    },
    {
      "Upstream Froude number range": "1.0 to 1.7",
      "Jump form": "Slight surface disturbance",
      "Behaviour described in HEC-14": "Upstream flow only slightly below critical depth; near 1.7 downstream depth is about twice incoming depth and exit velocity about half",
      "Energy loss": "not stated"
    },
    {
      "Upstream Froude number range": "1.7 to 2.5",
      "Jump form": "Pre-jump with roller",
      "Behaviour described in HEC-14": "Roller begins and intensifies with Froude number; smooth surface and uniform velocity",
      "Energy loss": "about 20"
    },
    {
      "Upstream Froude number range": "2.5 to 4.5",
      "Jump form": "Oscillating jump",
      "Behaviour described in HEC-14": "Incoming jet alternates between bottom and surface; surface waves can cause downstream erosion",
      "Energy loss": "not stated"
    },
    {
      "Upstream Froude number range": "4.5 to 9.0",
      "Jump form": "Stable, well-balanced jump",
      "Behaviour described in HEC-14": "Turbulence mostly confined to the jump; comparatively smooth downstream surface",
      "Energy loss": "45 to 70"
    },
    {
      "Upstream Froude number range": "above 9.0",
      "Jump form": "Highly efficient jump",
      "Behaviour described in HEC-14": "Rough water surface may cause downstream erosion",
      "Energy loss": "not stated"
    }
  ],
  "sources": [
    {
      "title": "HEC-14 Hydraulic Design of Energy Dissipators for Culverts and Channels, 3rd ed., chapter 6",
      "url": "https://www.fhwa.dot.gov/engineering/hydraulics/pubs/06086/hec14.pdf",
      "accessed": "2026-11-15"
    }
  ]
}