  "name": "OSHA 29 CFR 1926 Construction Safety Engineering Thresholds Matrix",
  "description": "Comparative matrix of quantitative regulatory trigger heights, load factors of safety, mandatory inspection frequencies, and competent person designations across core subparts of 29 CFR 1926, compiled from official OSHA standards.",
  "page": "https://casrai.org/guides/osha-29-cfr-1926",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-14T03:43:29Z",
  "temporalCoverage": "2026",
  "spatialCoverage": "United States",
  "columns": [
    {
      "name": "Subpart and Operational Topic",
      "unit": "",
      "description": "Construction hazard category and activity under 29 CFR 1926"
    },
    {
      "name": "OSHA Standard Citation",
      "unit": "",
      "description": "Specific regulatory paragraph in Title 29 CFR Part 1926"
    },
    {
      "name": "Fall or Hazard Trigger Threshold",
      "unit": "ft",
      "description": "Height or depth at which specialized protective systems become mandatory"
    },
    {
      "name": "Minimum Factor of Safety",
      "unit": ":1",
      "description": "Structural safety factor required relative to maximum intended load"
    },
    {
      "name": "Mandatory Inspection Frequency",
      "unit": "",
      "description": "Required regulatory inspection interval by qualified personnel"
    },
    {
      "name": "Competent Person Requirement",
      "unit": "",
      "description": "Required specialized supervisory qualification under 1926.32(f)"
    }
  ],
  "rows": [
    {
      "Subpart and Operational Topic": "General Safety Provisions",
      "OSHA Standard Citation": "29 CFR 1926.20(b)(2)",
      "Fall or Hazard Trigger Threshold": 0,
      "Minimum Factor of Safety": 1,
      "Mandatory Inspection Frequency": "Frequent and regular",
      "Competent Person Requirement": "Designated Competent Person"
    },
    {
      "Subpart and Operational Topic": "Scaffolding Systems",
      "OSHA Standard Citation": "29 CFR 1926.451(a)(1)",
      "Fall or Hazard Trigger Threshold": 10,
      "Minimum Factor of Safety": 4,
      "Mandatory Inspection Frequency": "Before each work shift",
      "Competent Person Requirement": "Scaffold Competent Person"
    },
    {
      "Subpart and Operational Topic": "Suspension Scaffold Ropes",
      "OSHA Standard Citation": "29 CFR 1926.451(a)(4)",
      "Fall or Hazard Trigger Threshold": 10,
      "Minimum Factor of Safety": 6,
      "Mandatory Inspection Frequency": "Before each shift and continuous",
      "Competent Person Requirement": "Scaffold Competent Person"
    },
    {
      "Subpart and Operational Topic": "Fall Protection General",
      "OSHA Standard Citation": "29 CFR 1926.501(b)(1)",
      "Fall or Hazard Trigger Threshold": 6,
      "Minimum Factor of Safety": 2,
      "Mandatory Inspection Frequency": "Daily prior to use",
      "Competent Person Requirement": "Fall Protection Competent Person"
    },
    {
      "Subpart and Operational Topic": "Excavations and Trenches",
      "OSHA Standard Citation": "29 CFR 1926.652(a)(1)",
      "Fall or Hazard Trigger Threshold": 5,
      "Minimum Factor of Safety": 1.5,
      "Mandatory Inspection Frequency": "Daily prior to work and after rain",
      "Competent Person Requirement": "Excavation Competent Person"
    },
    {
      "Subpart and Operational Topic": "Steel Erection General",
      "OSHA Standard Citation": "29 CFR 1926.760(a)(1)",
      "Fall or Hazard Trigger Threshold": 15,
      "Minimum Factor of Safety": 2,
      "Mandatory Inspection Frequency": "Daily and shift-level",
      "Competent Person Requirement": "Qualified Steel Rigging Supervisor"
    },
    {
      "Subpart and Operational Topic": "Steel Connectors and Decking",
      "OSHA Standard Citation": "29 CFR 1926.760(b)(3)",
      "Fall or Hazard Trigger Threshold": 30,
      "Minimum Factor of Safety": 2,
      "Mandatory Inspection Frequency": "Continuous oversight",
      "Competent Person Requirement": "Qualified Steel Rigger"
    },
    {
      "Subpart and Operational Topic": "Cranes and Derricks",
      "OSHA Standard Citation": "29 CFR 1926.1412(d)",
      "Fall or Hazard Trigger Threshold": 0,
      "Minimum Factor of Safety": 5,
      "Mandatory Inspection Frequency": "Daily pre-shift inspection",
      "Competent Person Requirement": "Qualified Crane Inspector"
    },
    {
      "Subpart and Operational Topic": "Stairways and Ladders",
      "OSHA Standard Citation": "29 CFR 1926.1053(a)(1)",
      "Fall or Hazard Trigger Threshold": 4,
      "Minimum Factor of Safety": 4,
      "Mandatory Inspection Frequency": "Periodically and before each shift",
      "Competent Person Requirement": "Designated Competent Person"
    }
  ],
  "sources": [
    {
      "title": "OSHA 29 CFR Part 1926 Standards Index",
      "url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926",
      "accessed": "2026-11-13"
    },
    {
      "title": "Electronic Code of Federal Regulations - Title 29 Part 1926",
      "url": "https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926",
      "accessed": "2026-11-13"
    },
    {
      "title": "OSHA 29 CFR 1926 Subpart M - Fall Protection",
      "url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.501",
      "accessed": "2026-11-13"
    },
    {
      "title": "OSHA 29 CFR 1926 Subpart P - Excavations",
      "url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.652",
      "accessed": "2026-11-13"
    },
    {
      "title": "OSHA 29 CFR 1926 Subpart L - Scaffolds",
      "url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.451",
      "accessed": "2026-11-13"
    },
    {
      "title": "OSHA 29 CFR 1926 Subpart R - Steel Erection",
      "url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.760",
      "accessed": "2026-11-13"
    },
    {
      "title": "OSHA 29 CFR 1926 Subpart CC - Cranes and Derricks",
      "url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.1412",
      "accessed": "2026-11-13"
    }
  ]
}