  "name": "Pentane safety data: how a reference card and three supplier sheets compare",
  "description": "Side-by-side comparison of identity, classification, flash point, auto-ignition, explosive limits, transport entry and exposure limits for pentane as printed on the ILO/WHO International Chemical Safety Card 0534 and on three supplier safety data sheets (Columbus Chemical, Labbox, Air Liquide Malaysia), compiled from each document as published. The Air Liquide sheet titled Pentane describes a different substance (CAS 463-82-1).",
  "page": "https://casrai.org/guides/pentane-sds",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-19T10:35:00Z",
  "temporalCoverage": "Sheet revision dates 2014-2026",
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Property",
      "unit": "",
      "description": ""
    },
    {
      "name": "ICSC 0534 n-Pentane (ILO/WHO)",
      "unit": "",
      "description": ""
    },
    {
      "name": "Columbus Chemical n-Pentane 3933",
      "unit": "",
      "description": ""
    },
    {
      "name": "Labbox n-Pentane AGR",
      "unit": "",
      "description": ""
    },
    {
      "name": "Air Liquide Malaysia 'Pentane' ALM/SDS/133",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Property": "CAS number",
      "ICSC 0534 n-Pentane (ILO/WHO)": "109-66-0",
      "Columbus Chemical n-Pentane 3933": "109-66-0",
      "Labbox n-Pentane AGR": "109-66-0",
      "Air Liquide Malaysia 'Pentane' ALM/SDS/133": "463-82-1"
    },
    {
      "Property": "Document date",
      "ICSC 0534 n-Pentane (ILO/WHO)": "April 2014 card revision",
      "Columbus Chemical n-Pentane 3933": "Revision date 26 Aug 2024",
      "Labbox n-Pentane AGR": "Revision date 15 Jun 2026",
      "Air Liquide Malaysia 'Pentane' ALM/SDS/133": "Revision date 23 Jun 2021"
    },
    {
      "Property": "Physical state",
      "ICSC 0534 n-Pentane (ILO/WHO)": "Colourless liquid",
      "Columbus Chemical n-Pentane 3933": "Liquid (boiling point 36 C)",
      "Labbox n-Pentane AGR": "Liquid (boiling point 36.06 C)",
      "Air Liquide Malaysia 'Pentane' ALM/SDS/133": "Gas at 20 C (boiling point 9.5 C)"
    },
    {
      "Property": "Classification statements",
      "ICSC 0534 n-Pentane (ILO/WHO)": "Highly flammable liquid and vapour; drowsiness or dizziness; may be fatal if swallowed and enters airways; toxic to aquatic life",
      "Columbus Chemical n-Pentane 3933": "H225, H304, H336",
      "Labbox n-Pentane AGR": "H225, H304, H336, H411",
      "Air Liquide Malaysia 'Pentane' ALM/SDS/133": "H220, H280, H411"
    },
    {
      "Property": "Flammable category",
      "ICSC 0534 n-Pentane (ILO/WHO)": "Highly flammable liquid",
      "Columbus Chemical n-Pentane 3933": "Flammable liquids Category 2",
      "Labbox n-Pentane AGR": "Flammable liquids Category 2",
      "Air Liquide Malaysia 'Pentane' ALM/SDS/133": "Flammable gases Category 1"
    },
    {
      "Property": "Flash point (C)",
      "ICSC 0534 n-Pentane (ILO/WHO)": "-49 (closed cup)",
      "Columbus Chemical n-Pentane 3933": "-49",
      "Labbox n-Pentane AGR": "-40",
      "Air Liquide Malaysia 'Pentane' ALM/SDS/133": "Not applicable for gases"
    },
    {
      "Property": "Auto-ignition temperature (C)",
      "ICSC 0534 n-Pentane (ILO/WHO)": "260",
      "Columbus Chemical n-Pentane 3933": "No data available",
      "Labbox n-Pentane AGR": "285",
      "Air Liquide Malaysia 'Pentane' ALM/SDS/133": "450"
    },
    {
      "Property": "Explosive limits in air (vol %)",
      "ICSC 0534 n-Pentane (ILO/WHO)": "1.5 - 7.8",
      "Columbus Chemical n-Pentane 3933": "No data available",
      "Labbox n-Pentane AGR": "1.4 - 8",
      "Air Liquide Malaysia 'Pentane' ALM/SDS/133": "1.3 - 7.5"
    },
    {
      "Property": "Transport entry",
      "ICSC 0534 n-Pentane (ILO/WHO)": "UN 1265, class 3, packing group I",
      "Columbus Chemical n-Pentane 3933": "UN1265 Pentanes, class 3, packing group II (DOT)",
      "Labbox n-Pentane AGR": "UN 1265 Pentanes, class 3, packing group II (ADR)",
      "Air Liquide Malaysia 'Pentane' ALM/SDS/133": "UN 2044, class 2.1 (flammable gas)"
    },
    {
      "Property": "Occupational limit as printed",
      "ICSC 0534 n-Pentane (ILO/WHO)": "TLV 1000 ppm TWA; EU-OEL 3000 mg/m3 (1000 ppm)",
      "Columbus Chemical n-Pentane 3933": "ACGIH TLV 1000 ppm TWA",
      "Labbox n-Pentane AGR": "EU IOEL 1000 ppm; UK WEL 600 ppm (1800 mg/m3); Italy 667 ppm (2000 mg/m3)",
      "Air Liquide Malaysia 'Pentane' ALM/SDS/133": "ACGIH TWA 1000 ppm"
    },
    {
      "Property": "Sheet prepared under",
      "ICSC 0534 n-Pentane (ILO/WHO)": "Not applicable (card)",
      "Columbus Chemical n-Pentane 3933": "US OSHA Hazard Communication Standard (29 CFR 1910.1200)",
      "Labbox n-Pentane AGR": "REACH Regulation (EC) 1907/2006 as amended by (EU) 2020/878",
      "Air Liquide Malaysia 'Pentane' ALM/SDS/133": "Regulation (EU) 2015/830"
    }
  ],
  "sources": [
    {
      "title": "ILO/WHO ICSC 0534 n-Pentane",
      "url": "https://chemicalsafety.ilo.org/dyn/icsc/showcard.display?p_card_id=0534",
      "accessed": "2026-11-18"
    },
    {
      "title": "Columbus Chemical n-Pentane SDS 3933",
      "url": "https://www.columbuschemical.com/MSDS/SDS/n-Pentane,%203933.pdf",
      "accessed": "2026-11-18"
    },
    {
      "title": "Labbox n-Pentane AGR SDS",
      "url": "https://labbox.es/wp-content/uploads/FDS/SDS_EN_10368.pdf",
      "accessed": "2026-11-18"
    },
    {
      "title": "Air Liquide Malaysia Pentane SDS ALM/SDS/133",
      "url": "https://my.airliquide.com/sites/al_my/files/2024-07/sds-133-c5h12-bi.pdf",
      "accessed": "2026-11-18"
    }
  ]
}