  "name": "Laboratory Phenol Formulations: Safety, Exposure Limits, and Barrier Protection Matrix",
  "description": "Comparative safety and handling specifications across five standard laboratory phenol formulations, compiled from manufacturer Safety Data Sheets, OSHA 29 CFR 1910.1000 Table Z-1, and ASTM F739 permeation standards.",
  "page": "https://casrai.org/guides/phenol-sds",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-15T14:16:41Z",
  "temporalCoverage": "2024/2026",
  "spatialCoverage": "United States",
  "columns": [
    {
      "name": "Formulation",
      "unit": "",
      "description": "Chemical formulation or reagent mixture name"
    },
    {
      "name": "Physical State",
      "unit": "",
      "description": "Primary physical state at 20 degrees Celsius"
    },
    {
      "name": "GHS Signal Word",
      "unit": "",
      "description": "GHS signal word under OSHA Hazard Communication Standard"
    },
    {
      "name": "Key GHS Hazards",
      "unit": "",
      "description": "Primary GHS hazard classification codes"
    },
    {
      "name": "OSHA PEL TWA",
      "unit": "ppm",
      "description": "OSHA 8-hour permissible exposure limit with skin notation"
    },
    {
      "name": "Disposable Nitrile Breakthrough",
      "unit": "minutes",
      "description": "Typical ASTM F739 breakthrough time for 4 mil disposable nitrile"
    },
    {
      "name": "Recommended Glove Material",
      "unit": "",
      "description": "Optimal glove polymer for chemical barrier resistance"
    },
    {
      "name": "Waste Stream Classification",
      "unit": "",
      "description": "Required RCRA hazardous waste segregation category"
    }
  ],
  "rows": [
    {
      "Formulation": "Pure Crystalline Phenol (≥99%)",
      "Physical State": "Solid crystals",
      "GHS Signal Word": "Danger",
      "Key GHS Hazards": "H301, H311, H314, H331, H341, H373",
      "OSHA PEL TWA": 5,
      "Disposable Nitrile Breakthrough": "< 10",
      "Recommended Glove Material": "Butyl rubber or Neoprene",
      "Waste Stream Classification": "Toxic organic (non-halogenated)"
    },
    {
      "Formulation": "Liquefied Phenol (88–90% aqueous)",
      "Physical State": "Liquid",
      "GHS Signal Word": "Danger",
      "Key GHS Hazards": "H301, H311, H314, H331, H341, H373",
      "OSHA PEL TWA": 5,
      "Disposable Nitrile Breakthrough": "< 10",
      "Recommended Glove Material": "Butyl rubber or Neoprene",
      "Waste Stream Classification": "Toxic organic (non-halogenated)"
    },
    {
      "Formulation": "TE-Buffered Phenol (pH 7.5–8.0)",
      "Physical State": "Liquid (biphasic)",
      "GHS Signal Word": "Danger",
      "Key GHS Hazards": "H301, H311, H314, H331, H341, H373",
      "OSHA PEL TWA": 5,
      "Disposable Nitrile Breakthrough": "< 15",
      "Recommended Glove Material": "Butyl rubber or Silver Shield",
      "Waste Stream Classification": "Toxic organic (non-halogenated)"
    },
    {
      "Formulation": "Phenol:Chloroform:Isoamyl Alcohol (25:24:1)",
      "Physical State": "Liquid (dense organic)",
      "GHS Signal Word": "Danger",
      "Key GHS Hazards": "H301, H311, H314, H331, H351, H361d, H372",
      "OSHA PEL TWA": 5,
      "Disposable Nitrile Breakthrough": "< 2",
      "Recommended Glove Material": "Viton or Silver Shield laminate",
      "Waste Stream Classification": "Halogenated organic waste"
    },
    {
      "Formulation": "Acid Guanidinium-Phenol (TRIzol-type)",
      "Physical State": "Liquid",
      "GHS Signal Word": "Danger",
      "Key GHS Hazards": "H301, H311, H314, H331, H341, H412",
      "OSHA PEL TWA": 5,
      "Disposable Nitrile Breakthrough": "< 10",
      "Recommended Glove Material": "Butyl rubber or double Nitrile",
      "Waste Stream Classification": "Toxic organic (chemical-specific)"
    }
  ],
  "sources": [
    {
      "title": "PubChem Compound Summary: Phenol (CID 996)",
      "url": "https://pubchem.ncbi.nlm.nih.gov/compound/Phenol",
      "accessed": "2026-11-15"
    },
    {
      "title": "OSHA 29 CFR 1910.1000 Table Z-1: Air Contaminants",
      "url": "https://www.law.cornell.edu/cfr/text/29/1910.1000",
      "accessed": "2026-11-15"
    },
    {
      "title": "Sigma-Aldrich Phenol Safety Data Sheet (Product 242322)",
      "url": "https://www.sigmaaldrich.com/US/en/sds/sial/242322",
      "accessed": "2026-11-15"
    },
    {
      "title": "Ansell Chemical Resistance Guide (Permeation Database)",
      "url": "https://www.ansell.com",
      "accessed": "2026-11-15"
    },
    {
      "title": "Fisher Scientific Phenol SDS (Product BP568)",
      "url": "https://www.fishersci.com",
      "accessed": "2026-11-15"
    }
  ]
}