{
  "name": "Non-compartmental PK parameters: definition and where two published Phoenix WinNonlin studies report them",
  "description": "Cross-walk compiled for this page. Definitions of standard NCA parameters come from MathWorks' SimBiology NCA documentation (read 2026-11-19); the last two columns record whether the Browne et al. 2018 tuberculosis study and the Sun et al. 2026 diclofenac bioequivalence study state that parameter in the abstract or methods text read. Yes means stated, No means not stated in the text read.",
  "page": "https://casrai.org/guides/phoenix-winnonlin",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-19T16:19:18Z",
  "temporalCoverage": null,
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Parameter",
      "unit": "",
      "description": ""
    },
    {
      "name": "Definition",
      "unit": "",
      "description": "As documented by MathWorks for its NCA implementation"
    },
    {
      "name": "Reported by Browne et al. 2018",
      "unit": "",
      "description": ""
    },
    {
      "name": "Reported by Sun et al. 2026",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Parameter": "Cmax",
      "Definition": "Maximum observed concentration",
      "Reported by Browne et al. 2018": "Yes",
      "Reported by Sun et al. 2026": "Yes"
    },
    {
      "Parameter": "Tmax",
      "Definition": "Time at which the maximum observed concentration occurs",
      "Reported by Browne et al. 2018": "No",
      "Reported by Sun et al. 2026": "No"
    },
    {
      "Parameter": "AUC0-t (AUC0-last)",
      "Definition": "Area under the concentration-time curve up to the last measured time point",
      "Reported by Browne et al. 2018": "Yes (as AUC)",
      "Reported by Sun et al. 2026": "Yes (AUC0-t)"
    },
    {
      "Parameter": "AUC0-inf",
      "Definition": "AUC0-last plus an extrapolated tail from the terminal rate constant",
      "Reported by Browne et al. 2018": "No",
      "Reported by Sun et al. 2026": "Yes"
    },
    {
      "Parameter": "Terminal rate constant (lambda z)",
      "Definition": "Estimated by regressing log concentration on time over the last n terminal points; at least three points in SimBiology",
      "Reported by Browne et al. 2018": "No",
      "Reported by Sun et al. 2026": "No"
    },
    {
      "Parameter": "Half-life (t1/2)",
      "Definition": "ln(2) divided by lambda z",
      "Reported by Browne et al. 2018": "Yes",
      "Reported by Sun et al. 2026": "No"
    },
    {
      "Parameter": "Clearance (CL, or CL/F after oral dosing)",
      "Definition": "Dose divided by AUC0-inf for single dosing; CL/F is apparent clearance",
      "Reported by Browne et al. 2018": "Yes (CL/F)",
      "Reported by Sun et al. 2026": "No"
    },
    {
      "Parameter": "Ctrough",
      "Definition": "Concentration at the end of a dosing interval; not defined in the MathWorks page read",
      "Reported by Browne et al. 2018": "Yes",
      "Reported by Sun et al. 2026": "No"
    }
  ],
  "sources": [
    {
      "title": "MathWorks: Non-compartmental analysis (SimBiology)",
      "url": "https://www.mathworks.com/help/simbio/ug/non-compartmental-analysis.html",
      "accessed": "2026-11-19"
    },
    {
      "title": "Browne SH et al., Clin Pharmacol Ther 2018 (PMC5836848)",
      "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC5836848/",
      "accessed": "2026-11-19"
    },
    {
      "title": "Sun B et al., Clin Pharmacol Drug Dev 2026 (Certara publication listing)",
      "url": "https://www.certara.com/publication/pharmacokinetics-bioequivalence-and-safety-of-diclofenac-sodium-sustained-release-tablets-in-healthy-chinese-subjects-under-fasting-and-fed-conditions/",
      "accessed": "2026-11-19"
    }
  ]
}