  "name": "Nucleic Acid Quantification Fluorophores and Optical Benchmarks",
  "description": "Comparative specifications of fluorometric dyes and optical methods for nucleic acid quantification compiled from manufacturer manuals and peer-reviewed characterization studies.",
  "page": "https://casrai.org/guides/picogreen-assay",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-14T20:52:00Z",
  "temporalCoverage": "1997/2026",
  "spatialCoverage": "Global",
  "columns": [
    {
      "name": "Reagent or Method",
      "unit": "",
      "description": "Assay or detection technology name"
    },
    {
      "name": "Target Nucleic Acid",
      "unit": "",
      "description": "Target analyte species"
    },
    {
      "name": "Excitation Peak",
      "unit": "nm",
      "description": "Excitation wavelength maximum"
    },
    {
      "name": "Emission Peak",
      "unit": "nm",
      "description": "Emission wavelength maximum"
    },
    {
      "name": "Lower Detection Limit",
      "unit": "pg/mL",
      "description": "Lowest measurable concentration in standard assay formats"
    },
    {
      "name": "Upper Linear Range",
      "unit": "ng/mL",
      "description": "Upper limit of linear quantification"
    },
    {
      "name": "Fluorescence Enhancement",
      "unit": "-fold",
      "description": "Increase in fluorescence emission upon target binding"
    }
  ],
  "rows": [
    {
      "Reagent or Method": "Quant-iT PicoGreen dsDNA (Low Range)",
      "Target Nucleic Acid": "Double-stranded DNA (dsDNA)",
      "Excitation Peak": 502,
      "Emission Peak": 523,
      "Lower Detection Limit": 25,
      "Upper Linear Range": 25,
      "Fluorescence Enhancement": 1000
    },
    {
      "Reagent or Method": "Quant-iT PicoGreen dsDNA (High Range)",
      "Target Nucleic Acid": "Double-stranded DNA (dsDNA)",
      "Excitation Peak": 502,
      "Emission Peak": 523,
      "Lower Detection Limit": 250,
      "Upper Linear Range": 1000,
      "Fluorescence Enhancement": 1000
    },
    {
      "Reagent or Method": "Quant-iT RiboGreen RNA (Low Range)",
      "Target Nucleic Acid": "Total / Single-stranded RNA",
      "Excitation Peak": 500,
      "Emission Peak": 525,
      "Lower Detection Limit": 1000,
      "Upper Linear Range": 50,
      "Fluorescence Enhancement": 1000
    },
    {
      "Reagent or Method": "Quant-iT RiboGreen RNA (High Range)",
      "Target Nucleic Acid": "Total / Single-stranded RNA",
      "Excitation Peak": 500,
      "Emission Peak": 525,
      "Lower Detection Limit": 20000,
      "Upper Linear Range": 1000,
      "Fluorescence Enhancement": 1000
    },
    {
      "Reagent or Method": "Hoechst 33258 Bisbenzimide Dye",
      "Target Nucleic Acid": "Double-stranded DNA (AT-rich)",
      "Excitation Peak": 352,
      "Emission Peak": 461,
      "Lower Detection Limit": 10000,
      "Upper Linear Range": 15000,
      "Fluorescence Enhancement": 30
    }
  ],
  "sources": [
    {
      "title": "Thermo Fisher Scientific Quant-iT PicoGreen dsDNA Reagent User Guide MAN0001931",
      "url": "https://assets.thermofisher.com/TFS-Assets/LSG/manuals/mp07581.pdf",
      "accessed": "2026-11-14"
    },
    {
      "title": "Singer et al. Characterization of PicoGreen reagent, Anal Biochem 1997",
      "url": "https://doi.org/10.1006/abio.1997.2177",
      "accessed": "2026-11-14"
    },
    {
      "title": "Thermo Fisher Scientific Quant-iT RiboGreen RNA Reagent User Guide MAN0001977",
      "url": "https://assets.thermofisher.com/TFS-Assets/LSG/manuals/mp11490.pdf",
      "accessed": "2026-11-14"
    },
    {
      "title": "Jones et al. RNA quantitation by RiboGreen reagent, Anal Biochem 1998",
      "url": "https://doi.org/10.1006/abio.1998.2914",
      "accessed": "2026-11-14"
    }
  ]
}