  "name": "Detection limits and membrane compatibility of general blot protein stains",
  "description": "Minimum protein detected per band and membrane compatibility for seven non-fluorescent blot membrane stains, compiled from Table 10.8.1 of the Current Protocols detection-of-proteins-on-blot-membranes unit; detection limits are based on protein loaded on a full-size gel.",
  "page": "https://casrai.org/guides/ponceau-s-staining-protocol",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-22T08:10:00Z",
  "temporalCoverage": "2016",
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Stain",
      "unit": "",
      "description": ""
    },
    {
      "name": "Minimum protein detected",
      "unit": "ng per band",
      "description": ""
    },
    {
      "name": "PVDF",
      "unit": "",
      "description": ""
    },
    {
      "name": "Nitrocellulose",
      "unit": "",
      "description": ""
    },
    {
      "name": "Nylon",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Stain": "Ponceau S",
      "Minimum protein detected": 200,
      "PVDF": "yes",
      "Nitrocellulose": "yes",
      "Nylon": "yes"
    },
    {
      "Stain": "Amido black",
      "Minimum protein detected": 50,
      "PVDF": "yes",
      "Nitrocellulose": "yes",
      "Nylon": "yes"
    },
    {
      "Stain": "Coomassie blue R-250",
      "Minimum protein detected": 50,
      "PVDF": "yes",
      "Nitrocellulose": "no",
      "Nylon": "yes"
    },
    {
      "Stain": "Colloidal gold",
      "Minimum protein detected": 2,
      "PVDF": "yes",
      "Nitrocellulose": "yes",
      "Nylon": "no"
    },
    {
      "Stain": "Colloidal silver",
      "Minimum protein detected": 5,
      "PVDF": "yes",
      "Nitrocellulose": "yes",
      "Nylon": "no"
    },
    {
      "Stain": "India ink",
      "Minimum protein detected": 5,
      "PVDF": "yes",
      "Nitrocellulose": "yes",
      "Nylon": "no"
    },
    {
      "Stain": "MemCode",
      "Minimum protein detected": 25,
      "PVDF": "yes",
      "Nitrocellulose": "yes",
      "Nylon": "no"
    }
  ],
  "sources": [
    {
      "title": "Detection of Proteins on Blot Membranes, Curr Protoc Protein Sci 2016",
      "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC5646381",
      "accessed": "2026-11-12"
    }
  ]
}