  "name": "Progressing cavity pump protection evidence across manufacturers",
  "description": "An original compilation of three operational concerns from SEEPEX and Liberty manufacturer operating manuals and the Sulzer PC transfer product reference. Rows distinguish the stated mechanism from the corresponding protection or design consideration; these are not machine-specific settings.",
  "page": "https://casrai.org/guides/progressing-cavity-pump",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-15T21:01:26Z",
  "temporalCoverage": null,
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Concern",
      "unit": "",
      "description": ""
    },
    {
      "name": "Documented mechanism or operating issue",
      "unit": "",
      "description": ""
    },
    {
      "name": "Documented protection or design consideration",
      "unit": "",
      "description": ""
    },
    {
      "name": "Evidence source",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Concern": "Dry running",
      "Documented mechanism or operating issue": "Rotor-stator friction raises stator temperature",
      "Documented protection or design consideration": "Prevent complete loss of suction-side flow; dry-running protection where continuous supply is not guaranteed",
      "Evidence source": "SEEPEX MD overview, section 6.5.2"
    },
    {
      "Concern": "Closed discharge",
      "Documented mechanism or operating issue": "Positive displacement operation with a closed outlet can damage pump and drive",
      "Documented protection or design consideration": "Open discharge path or a relief-valve or bypass arrangement",
      "Evidence source": "Liberty Series manual, section 2.4.2"
    },
    {
      "Concern": "Abrasive wear",
      "Documented mechanism or operating issue": "Abrasive applications require attention to pump wear",
      "Documented protection or design consideration": "Low-running-speed drive options are offered to reduce wear",
      "Evidence source": "Sulzer PC transfer, main design features"
    }
  ],
  "sources": [
    {
      "title": "SEEPEX MD Operating and Maintenance Instructions, overview",
      "url": "https://www.egm-llc.com/pdfs/iomanuals/seepex_range_md_progressive_cavity_pump.pdf",
      "accessed": "2026-11-15"
    },
    {
      "title": "Liberty Series Installation, Operation and Maintenance Manual",
      "url": "https://progressivepumps.com/wp-content/uploads/2018/04/liberty_series_progressive_cavity_pump_manual.pdf",
      "accessed": "2026-11-15"
    },
    {
      "title": "Sulzer PC transfer pump",
      "url": "https://www.sulzer.com/en/shared/products/pc-transfer-pump",
      "accessed": "2026-11-15"
    }
  ]
}