  "name": "Protein lyophilization stresses mapped to protective and unsuitable formulation choices",
  "description": "Compiled by CASRAI from a 2024 formulation review of lyophilized protein drug products and a 2015 review of protein structure in lyophilized solids. Each row pairs a stress with what the sources say protects against it and what does not. Values and wording follow the sources.",
  "page": "https://casrai.org/guides/protein-lyophilization",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-21T01:30:10Z",
  "temporalCoverage": "2015/2024",
  "spatialCoverage": null,
  "columns": [
    {
      "name": "Stress",
      "unit": "",
      "description": ""
    },
    {
      "name": "Stage",
      "unit": "",
      "description": ""
    },
    {
      "name": "What happens",
      "unit": "",
      "description": ""
    },
    {
      "name": "Protective choice named in the source",
      "unit": "",
      "description": ""
    },
    {
      "name": "Choice that does not help or is discouraged",
      "unit": "",
      "description": ""
    },
    {
      "name": "Source",
      "unit": "",
      "description": ""
    }
  ],
  "rows": [
    {
      "Stress": "Cold denaturation",
      "Stage": "Freezing",
      "What happens": "Spontaneous unfolding at temperatures well below 0 °C; not inevitable if unfolding is slow in a viscous frozen formulation",
      "Protective choice named in the source": "Sugars and polyols such as sucrose and trehalose at sufficient amount",
      "Choice that does not help or is discouraged": "Not stated as a PEG-type effect",
      "Source": "Cheng et al. 2024"
    },
    {
      "Stress": "Freeze-concentration and pH shift",
      "Stage": "Freezing",
      "What happens": "Solutes, metals, reactive oxygen species and proteases concentrate; differential buffer crystallization can shift pH by 3 units or more",
      "Protective choice named in the source": "Buffers that do not crystallize on freezing (for example histidine, Tris, citrate); phosphate at 20 mM or lower, or with trehalose or sucrose",
      "Choice that does not help or is discouraged": "High-concentration sodium phosphate; volatile buffers such as acetate",
      "Source": "Cheng et al. 2024"
    },
    {
      "Stress": "Ice-water interface",
      "Stage": "Freezing",
      "What happens": "Denaturation at protein-ice interfaces",
      "Protective choice named in the source": "Surfactant above its critical micelle concentration, kept limited",
      "Choice that does not help or is discouraged": "Excess polysorbate, whose peroxide impurities can oxidize protein",
      "Source": "Cheng et al. 2024"
    },
    {
      "Stress": "Phase separation",
      "Stage": "Freezing",
      "What happens": "Liquid-liquid or crystalline-amorphous separation can deplete stabilizers from the protein",
      "Protective choice named in the source": "Formulation chosen so stabilizers stay with the protein (for example amorphous arginine HCl, per the review)",
      "Choice that does not help or is discouraged": "Components that crystallize or separate",
      "Source": "Cheng et al. 2024"
    },
    {
      "Stress": "Dehydration",
      "Stage": "Drying",
      "What happens": "Loss of water hydrogen bonds at the protein surface",
      "Protective choice named in the source": "Sucrose and trehalose replace water in hydrogen bonds",
      "Choice that does not help or is discouraged": "PEG and similar polymers; reducing sugars (glucose, lactose) because of Maillard glycation",
      "Source": "Cheng et al. 2024"
    },
    {
      "Stress": "Storage above or below Tg",
      "Stage": "Storage",
      "What happens": "Above Tg is usually less stable, but below Tg is not sufficient: insulin deamidated and dimerized while glassy below 12% humidity; G6PD kept about 80% activity with sucrose versus about 50% with 100% raffinose after 81 days despite a higher Tg",
      "Protective choice named in the source": "Sucrose-rich formulation (G6PD example)",
      "Choice that does not help or is discouraged": "Relying on Tg alone as a predictor",
      "Source": "Moorthy et al. 2015"
    }
  ],
  "sources": [
    {
      "title": "Cheng et al. 2024, Practical advice in the development of a lyophilized protein drug product (PMC)",
      "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC11744310/",
      "accessed": "2026-11-20"
    },
    {
      "title": "Moorthy, Iyer, Topp 2015, Characterizing protein structure in lyophilized solids (PMC)",
      "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC4671836",
      "accessed": "2026-11-20"
    },
    {
      "title": "Mutukuri et al. 2021, Freeze drying vs. spray freeze drying (PMC)",
      "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC7856218",
      "accessed": "2026-11-20"
    }
  ]
}