  "name": "Oncologic Imaging Modality Technical Benchmarks and Clinical Utility",
  "description": "Comparative specifications of diagnostic and functional imaging modalities utilized in oncologic staging, therapeutic response monitoring, and radiation treatment planning, compiled from NCI clinical guidelines and peer-reviewed imaging standards.",
  "page": "https://casrai.org/guides/radiology-imaging-cancer",
  "publisher": "CASRAI",
  "license": "https://creativecommons.org/licenses/by/4.0/",
  "dateModified": "2026-11-23T11:10:00Z",
  "temporalCoverage": "2024/2026",
  "spatialCoverage": "International",
  "columns": [
    {
      "name": "Modality",
      "unit": "",
      "description": "Diagnostic imaging system classification"
    },
    {
      "name": "Typical Spatial Resolution",
      "unit": "mm",
      "description": "In-plane reconstructed spatial resolution threshold"
    },
    {
      "name": "Scan Acquisition Time",
      "unit": "minutes",
      "description": "Standard clinical patient examination duration"
    },
    {
      "name": "Ionizing Radiation Dose",
      "unit": "mSv",
      "description": "Typical adult effective radiation dose range per standard exam"
    },
    {
      "name": "Standard Contrast / Tracer Agent",
      "unit": "",
      "description": "Primary clinical pharmaceutical or radiopharmaceutical administered"
    },
    {
      "name": "Primary Response Evaluation Standard",
      "unit": "",
      "description": "Clinical trial and oncologic response assessment criteria"
    }
  ],
  "rows": [
    {
      "Modality": "Computed Tomography (Contrast CT)",
      "Typical Spatial Resolution": 0.7,
      "Scan Acquisition Time": 10,
      "Ionizing Radiation Dose": 7,
      "Standard Contrast / Tracer Agent": "Iohexol / Iopamidol (iodinated)",
      "Primary Response Evaluation Standard": "RECIST 1.1 (Sum of Diameters)"
    },
    {
      "Modality": "Magnetic Resonance Imaging (Multiparametric MRI)",
      "Typical Spatial Resolution": 1.2,
      "Scan Acquisition Time": 35,
      "Ionizing Radiation Dose": 0,
      "Standard Contrast / Tracer Agent": "Gadobutrol / Gadoterate (GBCA)",
      "Primary Response Evaluation Standard": "RECIST 1.1 / Organ-specific RADS"
    },
    {
      "Modality": "18F-FDG Positron Emission Tomography (PET/CT)",
      "Typical Spatial Resolution": 4.5,
      "Scan Acquisition Time": 25,
      "Ionizing Radiation Dose": 10,
      "Standard Contrast / Tracer Agent": "Fluorodeoxyglucose (18F-FDG)",
      "Primary Response Evaluation Standard": "PERCIST 1.0 (SULpeak reduction)"
    },
    {
      "Modality": "Diagnostic Ultrasound (High-Frequency US)",
      "Typical Spatial Resolution": 0.6,
      "Scan Acquisition Time": 15,
      "Ionizing Radiation Dose": 0,
      "Standard Contrast / Tracer Agent": "Sulfur hexafluoride microbubbles (CEUS)",
      "Primary Response Evaluation Standard": "Morphologic measurement / BI-RADS"
    },
    {
      "Modality": "Cone-Beam Computed Tomography (Onboard CBCT)",
      "Typical Spatial Resolution": 1.5,
      "Scan Acquisition Time": 2,
      "Ionizing Radiation Dose": 2.5,
      "Standard Contrast / Tracer Agent": "None (unenhanced localization)",
      "Primary Response Evaluation Standard": "IGRT volumetric target verification"
    }
  ],
  "sources": [
    {
      "title": "National Cancer Institute: Tests and Procedures Used to Diagnose Cancer",
      "url": "https://www.cancer.gov/about-cancer/diagnosis-staging/diagnosis",
      "accessed": "2026-11-20"
    },
    {
      "title": "Molecular Oncology: Imaging and cancer: A review",
      "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC5527766/",
      "accessed": "2026-11-20"
    },
    {
      "title": "Insights into Imaging: Assessing the reliability of Response Evaluation Criteria In Solid Tumors (RECIST)",
      "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC13319625/",
      "accessed": "2026-11-20"
    }
  ]
}